S.CON1M/MA System
31
•
S.CON1M/MA F/O port connected to Management
•
Device Temperature
Local status
:
Link BW FP SLE Remote device
TP FO Dn Up Pause AN DX DR T->F F->T Up Dn Type Power
========================================================================
On On 100M 100M On On FDX 100M On On Off Off H.CON/MA OK
========================================================================
FO port connected to Mgmt
Device temperature: 54c
Figure 10 - device status
Choosing option 2 in the main menu will list the device control menu (figure 11) this
menu enables you to reset the device and change its operating parameters.
Return to
the main menu by choosing 0.
Choosing option 3 in the main menu will list the
device Link management parameters (refer to figure 14)
Device control:
===============
]
1
[
Link configuration
]
2
[
FP/SLE control
]
3
[
Reset device
]
0
[
Back to main menu
Figure 11 - device control menu
Choosing option 1 in the Device control menu will list the Link Configuration menu.
Choosing option 2 will allow the selection of the Fault Propagation and SLE parameters
Option 3 will allow the reset of the S.CON1M/MA device.
Return to the main menu by
choosing 0 (figure 9).
Link configuration
:
===================
]
1
[
Set A/N mode
]
2
[
Set duplex mode
]
3
[
Set line data rate (10/100)
]
4
[
Set Pause mode
]
5
[
Set FO mgmt mode
]
0
[
Back to control menu
Figure 12 - device Link configuration
Choosing option 4 in the Link configuration menu will allow you to enable or disable
the Pause mode, which is used for Flow control in order to determine the Rate limiting.
FP/SLE control
:
===============
]
1
[
TP->FO FP mode
]
2
[
FO->TP FP mode
]
3
[
Downstream SLE mode
]
4
[
Upstream SLE mode
]
0
[
Back to channel control menu
Figure 13– terminal: device FP/SLE control