S.CON1M/MA System
12
6 – Installation
S.CON1M/MA all models (including –48 VDC models).
The device is intended for use with indoors power lines only
The S.CON1M/MA product is suitable for desktop, shelf or wall mount installation
For Desktop use
: Affix the supplied plastic “feet” (after peeling off the adhesive
protecting sheet) to the bottom of the devices, with each “foot” approximately 1 cm
from each edge. Place the device horizontally on a hard, clean surface (desk, shelf,
etc.), leaving free space around it for natural ventilation. Avoid placing the device on
other active, heat generating equipment and avoid placing such devices on other
S.CON1M/MA unit.
For wall mount installation
Attach the single channel wall mount kit (SCH – WM part # B161) with two (supplied)
screws to the base of the S.CON1M/MA unit (select any 2 adjacent nuts: 1+2 or 3+4
or1+3 or 2+4) to achieve the desired mode of mounting. The screws to be fixed on the
wall should not protrude more than 8mm. Append the S.CON1M/MA unit on the wall.
For Shelf installation:
Use the 19” Rack shelf (CTF-RM P/N B012) for installation of up to 3 S.CON1M/MA
units.
During the installation of several 19” Rack shelves, it is recommended to leave at least
1cm ventilation space between two adjacent racks.