S.CON1M/MA System
26
•
Trap destination
:
Trap destination (1-4)
: specify the IP address(es) of
the remote manager(s) that will receive the traps sent by the
S.CON1M/MA a maximum of 4 trap destinations. A 0.0.0.0 address is
ignored when traps are sent.
•
Trap community
: specify the trap community string for the media
converter.
( max. 15 characters ).
•
System name
: specify a name that identifies the converter.
(Max. 18 characters).
•
System location
: specify the physical location of the media converter.
Setting this parameter properly helps to monitor the network and maintain
order within it. (max. 18 characters).
•
Contact name
: specify the person (most likely system administrator) that is
responsible for managing and/or handling the system ( max. 18 characters).
•
User name
: the user name for login when starting a terminal session
through the serial connection or via Telnet. Maximum of 8 characters.
Default user name is ‘moose’. User name during login is case sensitive.
•
Password
: the password for login when starting a terminal session
through the serial connection or via Telnet. Maximum of 8 characters.
Default user name is ‘1234’. Password during login is case sensitive.
•
Start up delay
: specify how many seconds the CPU should wait between
the appearance of the start-up screen and the system initialization. During
this time it is possible to enter the system’s configuration.
Updating parameter storage. This may take a while...Done
Initialization...
Figure 3– configuration complete; initialization
The S.CON1M/MA is now ready. The Ready LED should now be lit steady.
Disconnect the control cable and store it properly.
Network Connection
1. Your media converter is capable of In-Band Management. In order to
achieve this follow these simple steps:
2. Make sure there is a network connection to the S.CON1M/MA
3. This connection can be made to either ports (TP and FO) of the
converter. However, this connection might depend on the device’s
configuration. In most cases, it is recommended that the connection be
obtained through the TP port (to prevent user intervention in
management). When S7 is set to UP position management is available
on both TP and F/O ports; DOWN position – on the local (TP) port only.
4. Verify the connection is active through the ping command (from the
management station to the S.CON1M/MA)