1. Overview and sub−bases for CPX I/O modules
1−21
Festo P.BE−CPX−EA−EN en 0804g
A
ssemb
ly
1
Cut the cable to
length and remove
the coating. Push the
union nut and the
seal insert onto the
end of the cable.
2
Insert the ends of the
core into the ap
propriate slots of the
splicing ring.
3
Place the seal and
the splicing ring to
gether and cut off the
projecting core ends
flush with the splicing
ring.
4
Insert the pre−fitted
splicing seal element
into the contact sup
port in the sub−base.
Screw in the union
nut as far as possible.
1
2
4
3
1
2
4
3
Fig.1/7: Connecting the cables to sub−base CPX−AB
D
ismant
l
ing
·
Loosen the screw connector and remove the cores by
pulling them out of the contacts.
The cores can be connected up to 10 times if the contact
ends are cut away each time (if the same core diameter is
used). Cut off the used cable ends and repeat steps 2 to 4.
Summary of Contents for VABA-10S6-X Series
Page 2: ......
Page 48: ...1 Overview and sub bases for CPX I O modules 1 30 Festo P BE CPX EA EN en 0804g...
Page 118: ...3 Digital CPX output modules 3 30 Festo P BE CPX EA EN en 0804g...
Page 119: ...Digital CPX multi I O modules 4 1 Festo P BE CPX EA EN en 0804g Chapter 4 Typ CPX 8DE 8DA...
Page 160: ...5 CPX pneumatic interfaces 5 24 Festo P BE CPX EA EN en 0804g...
Page 161: ...Technical appendix A 1 Festo P BE CPX EA EN en 0804g Appendix A...
Page 174: ...A Technical appendix A 14 Festo P BE CPX EA EN en 0804g...
Page 175: ...Internal structure and examples of cicuitry B 1 Festo P BE CPX EA EN en 0804g Appendix B...
Page 187: ...Index C 1 Festo P BE CPX EA EN en 0804g Appendix C...
Page 188: ...C Index C 2 Festo P BE CPX EA EN en 0804g Contents C Index C 1...