4. Digital CPX multi I/O modules
4−9
Festo P.BE−CPX−EA−EN en 0804g
4
.
4
I
nst
r
uctions
on
commissioning
The reaction of the I/O modules can be parameterized.
The table below gives an overview of the parameters.
Further information on parameterizing can be found in the
system manual or in the manual for the bus node.
4.4.1
Parameters of the multi I/O modules type CPX−8DE−8DA
Module
pa
r
amete
r
s
:
Monito
r
ing
t
h
e
C
P
X
module
Function no.
4828 + m * 64 + 0
m = module number (0
Ū
47)
Description
Monitoring of the possible faults can be activated or deactivated (suppressed)
for each module independently. Active monitoring causes the following:
The fault is:
sent to the CPX bus node
displayed by the module common error LED.
Bit
0
1
2
Surveillance
Description
Short circuit/overload in sensor supply (SCS)
Short circuit/overload at the outputs (SCO)
Undervoltage at outputs (V
OUT
)
[Monitor]
[Monitor SCS]
[Monitor SCO]
[Monitor Vout]
Values
1 = active (presetting)
0 = inactive
[Active]
[Inactive]
Note
Monitoring can also be set for the complete CPX terminal
(see System parameter monitoring").
Tab.4/5:
Monitoring the CPX module
Summary of Contents for VABA-10S6-X Series
Page 2: ......
Page 48: ...1 Overview and sub bases for CPX I O modules 1 30 Festo P BE CPX EA EN en 0804g...
Page 118: ...3 Digital CPX output modules 3 30 Festo P BE CPX EA EN en 0804g...
Page 119: ...Digital CPX multi I O modules 4 1 Festo P BE CPX EA EN en 0804g Chapter 4 Typ CPX 8DE 8DA...
Page 160: ...5 CPX pneumatic interfaces 5 24 Festo P BE CPX EA EN en 0804g...
Page 161: ...Technical appendix A 1 Festo P BE CPX EA EN en 0804g Appendix A...
Page 174: ...A Technical appendix A 14 Festo P BE CPX EA EN en 0804g...
Page 175: ...Internal structure and examples of cicuitry B 1 Festo P BE CPX EA EN en 0804g Appendix B...
Page 187: ...Index C 1 Festo P BE CPX EA EN en 0804g Appendix C...
Page 188: ...C Index C 2 Festo P BE CPX EA EN en 0804g Contents C Index C 1...