A. Technical appendix
A−7
Festo P.BE−CPVSC−E N en 0301a
Electric components
Electromagnetic compatibility
of the CPV−SC valve terminal with MP connection
Interference emitted
Resistance to interference
Tested as per EN 61000−6−4: (industry)
1)
Tested as per EN 61000−6−2 (industry)
2)
Protection against electric shock
(protection against direct and indirect contact as
per EN 60204−1/IEC 204)
By connection to a PELV power unit
(Protected Extra−Low Voltage)
Operating voltage
Tolerance
24 V DC
± 10 % (21.6...26.4 V DC)
Power consumption
(at 24 V, on the multipin plug)
Per valve solenoid coil
1 W
1)
The CPV−SC valve terminal is intended for industrial use.
2)
The maximum permitted signal cable length is 10 m.
Tab.A/4:
Technical specifications for the electric components
Please note
Data on the electric components of the CPV−SC valve
terminal with multipin connection are enclosed with the
product.
Summary of Contents for Smart cubic CPVSC1-VI
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPVSC EN en 0301a...
Page 12: ...Contents and general instructions X Festo P BE CPVSC EN en 0301a...
Page 13: ...Summary of components 1 1 Festo P BE CPVSC EN en 0301a Chapter 1...
Page 22: ...1 Summary of components 1 10 Festo P BE CPVSC EN en 0301a...
Page 23: ...Fitting 2 1 Festo P BE CPVSC EN en 0301a Chapter 2...
Page 31: ...Installation 3 1 Festo P BE CPVSC EN en 0301a Chapter 3...
Page 50: ...3 Installation 3 20 Festo P BE CPVSC EN en 0301a...
Page 51: ...Commissioning 4 1 Festo P BE CPVSC EN en 0301a Chapter 4...
Page 66: ...4 Commissioning 4 16 Festo P BE CPVSC EN en 0301a...
Page 67: ...Maintenance and conversion 5 1 Festo P BE CPVSC EN en 0301a Chapter 5...
Page 77: ...Technical appendix A 1 Festo P BE CPVSC EN en 0301a Appendix A...
Page 87: ...Index B 1 Festo P BE CPVSC EN en 0301a Appendix B...
Page 88: ...B Index B 2 Festo P BE CPVSC EN en 0301a Contents B Index B 1 B 1 Index B 3...