5. Maintenance and conversion
5-6
Festo P.BE-CPVSC-EN en 0112NH
4. Pull the component forwards so that it can be discon-
nected from the plug of the electric circuit. Then lift it up
slightly and pull it forwards away from the tie rod.
Fig. 5/2: Removing a component in a valve location
Fitting a component
Please note
The valve with the work connection sub-base is a unit
tested for leakage by Festo.
– Do
not
disconnect the screw connectors in the work
connection sub-base.
They guarantee that the unit does not leak.
Proceed as follows:
1. Make sure that the seals are correctly seated between the
components on the valve terminal. They must lie correctly
in the appropriate seal grooves.