![Festo s CMMD-AS-C8-3A Mounting And Installation Download Page 72](http://html1.mh-extra.com/html/festo/s-cmmd-as-c8-3a/s-cmmd-as-c8-3a_mounting-and-installation_2283257072.webp)
B
Diagnostic messages
72
Festo – GDCP-CMMD-AS-HW-EN – 1404NH – English
B.4
Profibus diagnostics
Diagnostic messages
Unit_Diag_Bit
no.
Message
Reaction
00
E429
“Position dataset”
42-9
Error in position data record
PS off
01
E703
“Operating mode”
70-3
Operating mode error
configurable
02
E702
“Arithmetic error”
70-2
General arithmetic error
PS off
03
E421
“Position precomputation”
42-1
Positioning: Error in pre-computa-
tion
configurable
04
E163
“Unexpected state”
16-3
Unexpected status / program-
ming error
PS off
05
E010
“Stack overflow”
01-0
Stack overflow (internal error)
PS off
06
E261
“Checksum error”
26-1
Checksum error
PS off
07
E162
“Initialization”
16-2
Initialization fault
PS off
08
E290
“No SD available”
29-0
No SD available
configurable
09
E291
“SD initialization”
29-1
SD initialization error
configurable
10
E292
“SD parameter set”
29-2
SD parameter set error
configurable
13
E222
“PROFIBUS
communication”
22-2
PROFIBUS communication error
configurable
14
-
“unknown”
12-0
CAN: general error
configurable
12-1
CAN: error bus off
configurable
12-2
CAN: Error when transmitting
configurable
12-3
CAN: Error when receiving
configurable
12-5
CAN: Error in the IPO mode
configurable
15
E790
“RS232 communication
error”
79-0
RS232 communication error
configurable
16
E761
“SSIO communication”
76-1
Error SSIO communication
(axis 2)
configurable
17
E760
“SSIO communication”
76-0
Error SSIO communication
(axis 1 - axis 2)
configurable
18
E418
“Record seq. Unknown
cmd”
41-9
Error in path program jump des-
tination
configurable
19
E419
Record seq. Invalid dest.”
41-8
Path program error, unknown
command
configurable
20
“unknown”
64-1
DeviceNet general error
PS off
64-2
DeviceNet communication error
PS off
64-3
DeviceNet communication error
PS off
64-4
DeviceNet communication error
PS off
64-5
DeviceNet communication error
PS off
64-6
DeviceNet communication error
PS off
65-0
DeviceNet general error
configurable
65-1
DeviceNet communication error
configurable
23
E220
“PROFIBUS assembly”
22-0
Error in PROFIBUS initialization
PS off
26
E351
“Time out: Quick stop”
35-1
Time out with fast stop
PS off