![Festo s CMMD-AS-C8-3A Mounting And Installation Download Page 17](http://html1.mh-extra.com/html/festo/s-cmmd-as-c8-3a/s-cmmd-as-c8-3a_mounting-and-installation_2283257017.webp)
2
Product Overview
Festo – GDCP-CMMD-AS-HW-EN – 1404NH – English
17
S1.9 … 10
ON/OFF (example)
Significance
1)
9
ON
1
DIL switch S1.9 is the low-order bit.
00:
125 kBit/s
01:
250 kBit/s (example)
10:
500 kBit/s
11:
1000 kBit/s
10
OFF
0
1)
Additional information
Description of functions and commissioning, GDCP-CMMS/D-FW-....
Tab. 2.6
CAN bus transmission rate
2.4.4
Slot [EXT 1/2]
The slot (
Fig. 2.2
4
) enables the option of expanding CMMD-AS-C8-3A by other interfaces, e.g..:
Interface
Brief description
Permitted slot
CAMC-D-8E8A
Interface for additional I/O
EXT 1
EXT 2
CAMC-PB
Interface for PROFIBUS DP
EXT 1
–
CAMC-DN
Interface for DeviceNet
EXT 1
–
Tab. 2.7
A CAN interface is rigidly integrated in the motor controller. As an option, an interface for PROFIBUS or
for DeviceNet can be integrated. However, a field bus interface can always be used for both axes. This
must be located in the slot [Ext 1].
For installation, please observe the assembly instructions for the CAMC interface. If the
interface is installed, it is automatically activated the next time the motor controller is
switched on. Information about function can be found in the FHPP device profile descrip-
tion, GDCP-CMMS-/D-C-HP-...
2.4.5
Card slot [M1] for SD memory card
A parameter set can be loaded from/saved onto the memory card by using the FCT soft-
ware. Additional information
Help for FCT plugIn CMMD-AS and description of function
and commissioning, GDCP-CMMS/D-FW-....