![Festo s CMMD-AS-C8-3A Mounting And Installation Download Page 47](http://html1.mh-extra.com/html/festo/s-cmmd-as-c8-3a/s-cmmd-as-c8-3a_mounting-and-installation_2283257047.webp)
A
Technical appendix
Festo – GDCP-CMMD-AS-HW-EN – 1404NH – English
47
A
Technical appendix
A.1
Technical data
General technical data
Type of mounting
Screwed to a mounting plate
Fault signal
7-segment display (error code)
Parameterisation interface
RS232 (9600 … 115 000 bit/s)
Parameterisation software
Festo Configuration Tool (FCT)
Control interfaces
fieldbus,
–
integrated: CANopen, RS485
–
optional: PROFIBUS DP, DeviceNet
Digital I/O
Analogue I/O
–
DIN0 … 13, DOUT0 … 3
–
AMON/AGND, AIN0/#AIN0
Protective functions
–
Short circuit in output stage
–
Intermediate circuit over/undervoltage
–
Temperature monitoring for motor and power
section
–
I
2
t monitoring with early reduction in current
when motor shaft is blocked
Dimensions and weight
Dimensions
Fig. 3.1 and Tab. 3.1
Weight
[kg]
2.5
Product conformity and certifications
CE marking
(Declaration of conformity
www.festo.com)
In accordance with EU Machinery Directive
2006/42/EC
To EC Low Voltage Directive 2006/95/EC
In accordance with EU EMC Directive
2004/108/EC
1)
Additional certifications
UL/RCM mark/BIA
1)
The device is intended for use in an industrial environment. Outside of industrial environments, e.g. in commercial and mixed-res-
idential areas, actions to suppress interference may have to be taken.
Tab. A.1
Technical data, general