2. Commissioning
2-15
Festo P.BE-CPV-CO3-EN en 1201a
Note
Please note the following if the outputs are reset after
PLC stop, field bus interruption or fault:
– Single-solenoid valves move to the basic position.
– Double-solenoid valves remain in the current position.
– Mid-position valves move to the mid-position (depend-
ing on valve type: pressurized, exhausted or blocked).
2.3.6
Manufacturer Specific Condition Monitoring
Examples see section B.1.5.
2.3.7
Module parameters
Further information on the module parameters see
CPI system description CP-BE-CPX-CP-...