FENIX IMVICO
TK23 OPERATION MANUAL
61/81
Transmit data
Specific
character
ASCII Hex Decimal
SHIFT
{S
7B, 53
123, 83
CODE A
{A
7B, 41
123, 65
CODE B
{B
7B, 42
123, 66
CODE C
{C
7B, 43
123,67
FNC1
{1
7B, 31
123, 49
FNC2 {2
7B,32
123,
50
FNC3 {3
7B,
33
123,51
FNC4 {4
7B,34
123,
52
“{“
{{
7B, 7B
123, 123
[Example] Example data for printing “Ref. 258710”
In this example, the printer first prints “No.” Using CODE B, then prints the
following numbers using CODE C.
GS k
73 11 123 66 82 101 102 46 123 67 25 87 10
Fig. 4.2-
Code128
code example.
3. If the top of the bar code data is not the code set selection
character, the printer stops command processing and processes
the following data as normal data.
4. If the combination of “{“ and the following character does not apply
any special character, the printer stop command processing and
processes the following data as normal data.
5. If the printer receives characters that cannot be used in the
special code set, the printer stop command processing and
processes the following data as normal data.
6. The printer does not print HRI characters that correspond to the
shift characters or code set selection characters.
7. HRI character for the function character is space.
8. HRI characters for the control character (<00>H to <1F>H and
<7F>H) are space.
<Others>
Be sure to keep spaces on both right and left sides of a bar code. (Spaces
are different depending on the types of the bar code.)
[Reference]
GS h
,
GS w