FENIX IMVICO
TK23 OPERATION MANUAL
55/81
GS ( K 2 0 1 m
[Name]
Select the print density.
[Format]
ASCII
GS ( K 2
0 1 m
Hex
1D 28 4B 02 00 01
m
[Range] <F6>H
≤
m
≤
<FF>H or
<00>H
≤
m
≤
<0A>H
(corresponds to print density from -50% to +50%)
[Description]
•
m
specifies the print density.
•
If <F6>H
≤
m
≤
<FF>H, the print density set to be lighter (“<F6>” is the lightest)
than the standard density.
•
If
m
= <00>H, the print density is set as the standard.
•
If <01>
≤
m
≤
<0A>H, the print density is set to be darker (“<0A>” is the
darkest) than the standard density.
•
The print density in one line is always the same even if different density is set.
In this case, the last specified data for the print density is effective.
M
Dec Hex
Print Density
10 0A
+50%
9 09
+45%
8 08
+40%
7 07
+35%
6 06
+30%
5 05
+25%
4 04
+20%
3 03
+15%
2 02
+10%
1 01
+5%
0 00 Standard
-1 FF
-5%
-2 FE
-10%
-3 FD
-15%
-4 FC
-20%
-5 FB
-25%
-6 FA
-30%
-7 F9
-35%
-8 F8
-40%
-9 F7
-45%
-10 F6
-50%
[Default]
m
= <00>H
[Reference]
PROGRAMMING MODE