background image

mr.steam

®

Installation, Operation & Maintenance Manual

_________________________________________________________________________

10

GENERATOR DIAGRAM

MS90E - 400E

MSSuper1E-3E

_______________________________________

A

5

(127)

7

1

4

(184)

B

8

1

8

(206)

9

7

8

(251)

C

11

1

4

(392)

15

1

2

(394)

D

14

1

4

(392)

18

3

4

(476)

E

1

7

8

(48)

1

1

4

(32)

F

2

(51)

2

1

4

(57)

G

5

7

8

(149)

6

(152)

H

5

(127)

4

7

8

(124)

I

6

7

8

(175)

7

7

8

(200)

J

2

(51)

2

(51)

K

14

1

2

(368)

17

(432)

L

2

1

2

(64)

2

1

2

(64)

M

6

3

8

(162)

6

3

8

(162)

WATER INLET

3

8

” NPT

STEAM OUTLET

1

2

” NPT

SAFETY VALVE

3

4

” NPT

MANUAL DRAIN VALVE

1

2

” NPT

AUTOFLUSH VALVE

1

2

” NPT

1. M = Optional AutoFlush
2. All units in inches (MM)

J

Water Inlet

Control &

Accessory

Connections

Steam Outlet

Safety Valve

Optional AutoFlush

IMPORTANT NOTES:

Provide a minimum of (12) inches at both ends and top of
the steam generator or as required for servicing. Alternately,
provide unions as required to facilitate installation and dis-
connection of the steam generator.

The minimum clearance from combustible surfaces is zero
all around.

Side View Showing
Element Access Panel

Manual Drain Valve

I

N

S

T

A

L

L

E

R

All drawings are for illustrative purposes only

TO AVOID EQUIPMENT
DAMAGE DO NOT
CONNECT POWER
SUPPLY DIRECTLY TO
ELEMENTS !!!

Summary of Contents for mr. steam MS90E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ...our body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel an...

Page 3: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 4: ...genera tor control locations must be taken into account A 30 foot cable is standard Contact MrSteam to purchase an optional 60 ft cable PN 103990 60 for iTempo and AirTempo and PN 104117 60 for iStea...

Page 5: ...by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steamba...

Page 6: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 7: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 8: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 9: ...ng as permitted by codes 3 DO NOT use black galvanized PVC pipe or PEX except as noted below WATER SUPPLY 3 8 NPT 1 Connect to cold water line Water feed line may be flexible copper tubing braided hos...

Page 10: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 11: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 12: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 13: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 14: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 15: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 16: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 17: ...can be added 3 Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown DO NOT drain into a steam enclosure or any l...

Page 18: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 19: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 20: ...eam iTempo Plus and AirTempo 100476 2 Contactor 50A 2 pole MS90E 400E Single phase 99012 Contactor 50A 3 pole All 3 Phase Models 103453 Contactor 50A 4 pole MSSuper1E 3E 100471 2 Probe Assembly All Mo...

Page 21: ...l and or steam generator are locat ed accordingly An optional 60 foot cable is available PN 103990 60 for AirTempo and iTempo and PN 104117 60 for iSteam Contact a MrSteam technical service representa...

Page 22: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...

Page 23: ...temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 m...

Page 24: ...they can be irritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous...

Page 25: ...oration I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Fee...

Reviews: