background image

STEAM PIPING (

1

2

" NPT)

1. DO NOT install any valve in steam piping. Flow of steam must

be unobstructed.

2. Use 1/2-inch brass pipe or copper tubing from unit to steam

head as permitted by codes.

3. Insulate steam piping with fiberglass pipe insulation or similar

insulation rated 212° F or higher.

4. Pitch steam piping1/4" per foot towards steam head or steam

generator to avoid valleys and trapping of condensate.

Failure to pitch the steam piping as required for

condensate to drain, may cause condensate to block the flow of
steam. Blocking the steam flow may cause steam pressure to
discharge boiling water through the steamhead, resulting in a
scalding hazard. Blocking the flow of steam may cause steam to
discharge through the safety valve, resulting in a scalding hazard.

A 1.5" hole in the steam room is required to

mount the steamhead. For Linear steamhead, please refer to the
installation instructions.

SAFETY VALVE (

3

4

" NPT)

Where permitted by local codes, provide an outlet plumbing
connection for safety valve.

To insure proper and automatic safety valve

operation: DO NOT connect a shut off valve or a plug at safety
valve outlet. DO NOT connect a shut off valve or any obstruction
in steam supply pipe. DO NOT connect the safety-valve output
into the steam piping.

CONDENSATION PAN

MrSteam strongly recommends the use of a condensation pan in
the unlikely event of a plumbing leak. Check local plumbing
codes for receptor, trap and vent requirements. Condensation
pans drain by gravity. The condensation pan is equipped with an
integral 3/4" fitting. See page 17 for additional condensation
pan installation information.

Do not plumb the generator drain and conden-

sation pan drain together in such a way that will cause drain
water to back into condensation pan.

mr.steam

®

Installation, Operation & Maintenance Manual

_________________________________________________________________________

I

N

S

T

A

L

L

E

R

8

All drawings are for illustrative purposes only

INSTALLATION

PLUMBING

All plumbing shall be performed by a qualified licensed plumber
and in accordance with applicable National and local codes.
1. Use unions on all pipe connections.
2. Use only brass piping or rigid copper tubing as permitted

by codes.

3. DO NOT use black, galvanized, PVC pipe or PEX except as

noted below.

WATER SUPPLY (

3

8

" NPT)

1. Connect to cold water line.

Water feed line may be flexible copper tubing,

braided hose, PVC or PEX if permissible by local codes.

2. Provide a shut off valve in the water supply line upstream of

the steambath generator.

3. DO NOT overheat inlet solenoid valve with solder connections.

Overheating will damage parts.

4. Flush inlet water line thoroughly before making connection

to unit.

5. Strainer recommended upstream of feed water connection.
6. In order to reduce operating noise, reducing feed water pres-

sure to between 15 - 20 psi is recommended. Optional pres-
sure reducing valve part number 104198.

7. Provide anti-water hammer device as required.
8. Install an approved backflow preventer as required

by local codes.

DRAIN (

1

2

" NPT)

The drain from the generator should not share an

undersink trap, unless the generator is mounted higher than the
sink to prevent damage to the generator if the drain backs up.

A drain valve is provided to facilitate servicing.

Provide a drain line connection from steambath generator drain
valve according to National and local Codes. Check local plumb-
ing code for receptor, trap and vent requirements. Do not con-
nect Drain line and Safety Valve line together.

Unit drains by

gravity.

Do not plumb the generator drain and condensa-

tion pan drain together in such a way that will cause drain water
to back into condensation pan.

DO NOT drain into a steam enclosure or any

location where accidental contact with drain water may occur.
In the event of a power failure the AutoFlush System valve will
open and may discharge boiling water causing a scalding hazard.
DO NOT connect the drain valve to the steam piping

AROMASTEAM

If the optional AromaSteam Electronic Oil Delivery System
(

PN

:

MS AROMA

) is to be installed, a 90 degree

T

plumbing fitting

must be installed at a designated location on the steam piping.
See the MrSteam AromaSteam Operation and Instruction Manual
(

PN

: 100402) for installation information before the steam piping is

installed at the technical downloads section of www.mrsteam.com

Steam

Generator

Steam

Generator

Steam

Generator

Steam

Generator

Steam

Generator

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam

Generator

Steam
Piping

Steam

Head

Summary of Contents for mr. steam MS90E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ...our body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel an...

Page 3: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 4: ...genera tor control locations must be taken into account A 30 foot cable is standard Contact MrSteam to purchase an optional 60 ft cable PN 103990 60 for iTempo and AirTempo and PN 104117 60 for iStea...

Page 5: ...by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steamba...

Page 6: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 7: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 8: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 9: ...ng as permitted by codes 3 DO NOT use black galvanized PVC pipe or PEX except as noted below WATER SUPPLY 3 8 NPT 1 Connect to cold water line Water feed line may be flexible copper tubing braided hos...

Page 10: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 11: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 12: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 13: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 14: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 15: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 16: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 17: ...can be added 3 Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown DO NOT drain into a steam enclosure or any l...

Page 18: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 19: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 20: ...eam iTempo Plus and AirTempo 100476 2 Contactor 50A 2 pole MS90E 400E Single phase 99012 Contactor 50A 3 pole All 3 Phase Models 103453 Contactor 50A 4 pole MSSuper1E 3E 100471 2 Probe Assembly All Mo...

Page 21: ...l and or steam generator are locat ed accordingly An optional 60 foot cable is available PN 103990 60 for AirTempo and iTempo and PN 104117 60 for iSteam Contact a MrSteam technical service representa...

Page 22: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...

Page 23: ...temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 m...

Page 24: ...they can be irritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous...

Page 25: ...oration I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Fee...

Reviews: