mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
I
N
S
T
A
L
L
E
R
11
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Water
Feed
Liquid
Level Probe
AutoFlush Plug
and Play Connection
(
see page 16
)
Fuses
Contactor
Power Block
Power Supply
Knock-Out
Steam
Outlet
Field
Wiring
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Steam
Outlet
Liquid
Level Probe
AutoFlush Plug and
Play Connection
(see page 16)
Contactor
Power Supply
Knock-Out
Field
Wiring
Water
Feed
FIELD POWER WIRING
1. TO AVOID EQUIPMENT DAMAGE
DO NOT CONNECT POWER
SUPPLY DIRECTLY TO ELEMENTS!!!
2. L1, L2, Ground to be field wired
3. Super 1E 240/1 models are not sup-
plied with internal fusing.
4. All Drawings are for illustrative
purposes only. Consult with
qualified licensed electrician
for electrical installation.
Models MS90E – MS400E
(single phase wiring shown)
Models MSSUPER1E - 3E
(single phase wiring shown)
ELECTRICAL
All electrical wiring to be installed by
a qualified licensed electrician in accordance with
National Electrical Code and local electrical code.
POWER WIRING
See “Field Power Wiring” Diagrams (below)
1. Check power voltage. Use 240V rated unit when supply
is greater than 208V. (Most homes have 240V, 1PH
service). Use 208V rated unit for 208V power.
2. Use minimum 90˚ C/300V rated insulated copper
conductors only, sized in accordance with National
Electrical Code and local electrical code for the current
in Ampere Chart. If allowed by codes, NM cable may
require a larger wire size than as listed on the chart.
3. Connect suitably sized equipment grounding wire to
ground terminal provided.
4. Install a separate circuit breaker between supply and
unit. Provide a power supply disconnect within sight
of the steam generator or one that is capable of being
locked in the open position.
5. For single phase units, use two-wire supply source and
equipment grounding wire. Neutral (white) wire is not
required.
E L E C T R I C A L C H A R T
________________________________________________________________________________________________________
Vol
Max Room
Wire Size
Wire Size
Model No. (Cu. Ft.*)
KW
Volts
†
Phase
Amps
(AWG)for 40˚ C (AWG) for 45˚ C
Ambient
Ambient
________________________________________________________________________________________________________
208
1
24
10
8
MS90E
100
5.0
3
14
12
12
240
1
21
10
10
3
12
12
12
________________________________________________________________________________________________________
208
1
29
8
8
MS150E
150
6.0
3
17
10
10
240
1
25
8
8
3
14
12
12
________________________________________________________________________________________________________
208
1
36
8
8
MS225E
225
7.5
3
21
10
10
240
1
32
8
8
3
18
10
10
________________________________________________________________________________________________________
208
1
44
8
6
MS400E
360
9.0
3
25
8
8
240
1
38
8
8
3
22
10
10
________________________________________________________________________________________________________
208
1
49
6
6
MSSuper
475
10.0
3
28
8
8
1E
240
1
42
8
6
3
24
8
8
________________________________________________________________________________________________________
208
1
58
6
4
MSSuper
575
12.0
3
34
8
8
2E
240
1
50
6
6
3
29
8
8
________________________________________________________________________________________________________
208
1
73
4
3
MSSuper
675
15.0
3
42
8
6
3E
240
1
63
4
4
3
36
8
8
________________________________________________________________________________________________________
*See page 3 for room sizing.
†
All specifications shown are for 208V and 240V Consult factory for other voltage specifications.
PROVIDE A POWER SUPPLY DISCONNECT WITHIN SIGHT OF THE STEAM GENERATOR OR ONE
THAT IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION AS REQUIRED BY CODE.