background image

mr.steam

®

Installation, Operation & Maintenance Manual

__________________________________________________________________________

I

N

S

T

A

L

L

E

R

5

LOCATING THE STEAM GENERATOR

S

elect a location as near as practical to the steam room.

Typical locations include: closet, vanity cabinet, heated attic or basement.

The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam genera-

tor and control must be located accordingly. A 60 foot cable is available as a special order part for iTempo

®

and AirTempo

®

, PN

103990-60 and PN 104117-60 for iSteam

®

. The maximum cable length is 60 feet.

IMPORTANT NOTE:

The control cable should be run in a dedicated 1" conduit to facilitate installation and service.

DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit

together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.

(Items 1-4)

1.

DO NOT

install steambath generator inside steam room,

a shock hazard will occur

2.

DO NOT

install steambath generator outdoors or wher-

ever environmental conditions may result in a shock haz-
ard or affect performance of the generator.

3. To prevent damage to the steam generator or a fire haz-

ard

DO NOT

install steambath generator near

flammable or corrosive materials or chemicals such as
gasoline, paint thinners, or the like. Installation in areas
having high concentrations of chlorine (such as pool
equipment room) must be avoided.

4. Burn Hazard. Steam piping, safety valve, drain valve and

plumbing become hot during operation and remain hot
after shutdown for a period of time. Provide
appropriate protection, including insulating plumbing
lines. Avoid plumbing runs and steamhead locations that
can come in contact with bathers.

(Items 5-7)

5.

DO NOT

install steambath generator or plumbing lines in

unheated attic or any locations where water could freeze
and cause pipes to rupture and cause property damage.

6. Install steambath generator on a solid and level

surface. Provide supports under steam generator when
wall mounting. Keyhole slots are provided for wall mount-
ing. Insure the steam generator is properly secured and

level when mounting with keyhole slots to prevent dam-
age to the steam generator.

7. Install steambath generator in an upright position only

to prevent damage to the generator.

IMPORTANT NOTES: (Items 8-12)

8. Install anti-water hammer device as necessary.
9. Provide a minimum of (12) inches at both ends and top of

the steam generator or as required for servicing. See page 10.

10. Provide unions as required to facilitate installation

and disconnection of piping.

11. MrSteam controls can be located inside the steam room

or on the outside of the steam room. See the Control
Installation Manual for your specific control package for
specific details.

12. The MS series of steam generators are for residential

use only. Commercial or other nonresidential applications
void the warranty and may adversely affect product
performance and may represent a safety hazard.

MrSteam Generators (inclusive of the iTempo,

AirTempo and iSteam series Controls) are CE and UL listed.

Suitable for operation in ambient not

exceeding 45 °C (113˚ F)

WATER QUALITY INFORMATION

F

or optimum results, the water supply should be tested prior to installation. If the

mineral content exceeds the following recommended limits, various external treat-
ment processes are recommended to correct the problem.

An analysis of the on-site water must be made by a recognized and

reliable water treatment company to ascertain the existing condition and treatment
required.

Poor water quality can affect efficiency or result in steam generator damage. Water
contains impurities in solution and suspension. These impurities concentrate in the
generator. The concentration of these impurities increases as more feedwater is
introduced into the generator and steam is produced. If the suspended solids are
allowed to concentrate beyond certain limits, a deposit or “scale” will form on the
generator internal surfaces. This deposit can interfere with the proper generator
operation and cause generator failure. The concentration of these impurities is
generally controlled by the water quality and by periodic draining of the generator.

RECOMMENDED FEEDWATER
QUALITY

Hardness, ppm

8 – 85 (~0.5 – 5 gpg)

P-Alkalinity, ppm

85 – 410 (~5 – 24 gpg)

T. Alkalinity, ppm 200 – 500 (~7 – 0 gpg)
pH (strength of alkalinity)

8.0 – 11.4

Every 2 months, or more often in “hard”
water areas, the manual drain valve should
be opened fully flushing out accumulated
materials, salts and other particles which
are natural by-products of boiling water.

The optional AutoFlush System feature
automatically drains the MrSteam

®

genera-

tor following each use. A time delay allows
the water to cool down (about two hours)
before it drains by gravity for a safe and
gentle operation.

Summary of Contents for mr. steam MS90E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ...our body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel an...

Page 3: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 4: ...genera tor control locations must be taken into account A 30 foot cable is standard Contact MrSteam to purchase an optional 60 ft cable PN 103990 60 for iTempo and AirTempo and PN 104117 60 for iStea...

Page 5: ...by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steamba...

Page 6: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 7: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 8: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 9: ...ng as permitted by codes 3 DO NOT use black galvanized PVC pipe or PEX except as noted below WATER SUPPLY 3 8 NPT 1 Connect to cold water line Water feed line may be flexible copper tubing braided hos...

Page 10: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 11: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 12: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 13: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 14: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 15: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 16: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 17: ...can be added 3 Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown DO NOT drain into a steam enclosure or any l...

Page 18: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 19: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 20: ...eam iTempo Plus and AirTempo 100476 2 Contactor 50A 2 pole MS90E 400E Single phase 99012 Contactor 50A 3 pole All 3 Phase Models 103453 Contactor 50A 4 pole MSSuper1E 3E 100471 2 Probe Assembly All Mo...

Page 21: ...l and or steam generator are locat ed accordingly An optional 60 foot cable is available PN 103990 60 for AirTempo and iTempo and PN 104117 60 for iSteam Contact a MrSteam technical service representa...

Page 22: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...

Page 23: ...temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 m...

Page 24: ...they can be irritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous...

Page 25: ...oration I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Fee...

Reviews: