DO NOT route iSteam, AirTempo, iTempo/Plus,
iTempo, HomeWizard or iGenie control wiring inside conduit
together with power lines or close to hot water or steam piping.
Doing so may result in an inoperative or hazardous installation.
DO NOT alter or modify any MrSteam product. Doing so may
result in an inoperative or hazardous installation and will void the
UL listing and warranty.
IMPORTANT NOTES:
1. Turn power to the steam generator OFF before connect-
ing the control to the generator. Failure to turn the power
off will result in an inoperable control.
2. DO NOT operate iSteam, AirTempo, iTempo/Plus, iTempo,
HomeWizard or iGenie controls with other than a MrSteam
iSteam, AirTempo, or iTempo compatible steam generator.
MrSteam residential steam generators with serial numbers
lower than 900000, or any other brand of steam generator
are not to be operated with iTempo controls. Doing so
may result in an inoperative or hazardous installation.
If iSteam is used with a generator having serial number
less than 1174000, contact MrSteam technical support for
an upgraded PC board.
3. This document contains important safety, operation and
maintenance information. Leave this document with the
homeowner. Do not discard this document.
4. Discontinue use of the steam generator or control if the
steam generator is damaged or otherwise not functioning
properly. Operating a damaged steam generator may
result in an inoperative or hazardous installation
mr.steam
®
Installation, Operation & Maintenance Manual
_________________________________________________________________________
I
N
S
T
A
L
L
E
R
20
CONTROL ROUGH IN
Refer to Installation Instructions for the specific control
IMPORTANT NOTE:
The control cable should be run in a
dedicated 1” conduit to facilitate installation and service.
1. Determine the desired installation location of the con-
trol. The iSteam
®
, AirTempo
®
, iTempo
®
and iTempo/Plus
®
controls are designed to be installed inside or outside the
steam room as a matter of personal preference. If the con-
trol is in-stalled inside the steam room the control must be
located:
2. 4 - 5 feet above the floor near the bather seating area
3. The control features an integral temperature sensor.
Locate the control in a location representative of the
desired steam bathing temperatures. DO NOT locate
the control above or near the steam head or direct
steam emissions.
4. on a vertical wall
The iSteam and iTempo control cable length is 30 feet.
Insure that the control and/or steam generator are locat-
ed accordingly. An optional 60 foot cable is available, PN
103990-60 for AirTempo and iTempo and PN 104117-60 for
iSteam. Contact a MrSteam technical service representative if
a 60 foot cable is required. Excess control cable should be
neatly coiled and twisted into a figure 8. The AirTempo dongle
is provided with a 3 foot cable. The maximum cable length is
60 feet.
IMPORTANT NOTES:
• If the control is installed outside the steam room a Remote
Temperature Probe Part Number MSTS must be installed
inside the steam room, depending on the control.
• Insure MrSteam steam generator is iSteam, AirTempo or
iTempo compatible and has a serial number 900000 or high-
er. If iSteam is used with a generator having serial number
less than 1174000, contact MrSteam technical support for an
upgraded PC board.
• See instructions for the MSTS Temperature Probe (located in
the Control Installation Manual related to your specific control
package) before rough-in or installation of control.
BEFORE INSTALLING
Turn power to the steam generator OFF before connecting the
control to the generator. Failure to turn the power off will result in
an inoperable control.
To avoid unintentional steambath operation,
DO NOT locate the control where other controls, acces-
sories, shower heads, valves, body sprays or similar within
the shower could cause confusion or interfere with the
MrSteam control’s intended use and function.
DO NOT use any iSteam
®
, AirTempo
®
,
iTempo/Plus
®
, iTempo
®
, HomeWizard
®
or iGenie
®
controls
without reading and understanding its own manual and the
MrSteam steam generator Installation and Operation Manual.
Failure to read and understand these instructions may result
in an inoperative or hazardous installation.
A peel and stick warning sticker must be read
and permanently affixed in a conspicuous location near the
steam room. Failure to read and affix this warning sticker in a
conspicuous location may result in serious injury or death. .
Install the iSteam, AirTempo, iTempo or iTempo/Plus controls
according to installation instructions. Failure to install accord-
ing to instructions will result in an inoperative control or haz-
ardous overheating or inadequate heating of the steam room.
If an iSteam, AirTempo, iTempo or iTempo/Plus control is
installed outside the steam room a Remote Temperature
Probe (PN MSTS) must be installed inside the steam room
per installation instructions supplied with the Remote
Temperature Probe. Failure to install according to instructions
will result in an inoperative control and overheating of the
steam room.
CONTROL INSTALLATION
Refer to Control Manual for specific installation requirements