Pump Assembly Continued
Figure 60 - Positioning Flex Coupling On Shaft
3.
Slide the flexible coupling onto the motor
shaft until the end of the motor shaft is flush
with the end of the motor half of the flexible
coupling.
NOTES:
The motor shaft and its key should
NOT be touching the plates of the flexible cou
-
pling disc pack. Ensure that the motor shaft key
does not slide out of place or project past the
end of the motor shaft.
Figure 59 - Installing Motor Shaft Key
APPLY SYSTEM COMPLIANT
ANTI-SEIZE COMPOUND
2. Apply system compliant anti-seize com-
pound onto the motor shaft and install the
motor shaft key into the shaft keyway.
NOTES:
For installation without motor adapt-
er, skip to
Final Pump Alignment - No Motor
Adapter
.
Figure 58 - Separating Pump From Motor
Final Pump Alignment
1. Slightly loosen all precision leveling feet
jacking bolts and tighten the in-line jacking
bolt to separate the pump from the motor.