Pump Assembly Continued
7. Measure the motor adapter top and bottom
(“A” & “B”) gaps and continue adjustment
procedures until the gap (if any) between
the motor adapter and the motor is equal.
NOTES:
Acceptable motor adapter gap toler
-
ance specified in the
Pump Alignment Specifi
-
cations
section of this manual.
NOTES:
This step does not apply for units with
no motor adapter.
NOTES:
Record the “A” & “B” measured align
-
ment gap (if existent) in the
Start Up Record
section of this manual.
A
A
B
B
NO
YES
A ≠B
A = B
Figure 55 - Motor Adapter Top and Bottom Gap
Figure 54 - Precision Leveling Foot Adjustment
6.
Correct any uneven gaps that exist between
the motor and motor adapter by loosening
all precision leveling feet and adjusting the
leveling foot at the discharge end of the
pump. Complete by readjusting the rest of
the loosened leveling feet.
NOTES:
Re-check the inlet precision leveling
foot to make sure the motor adapter is properly
aligned with the motor. If necessary, make any
corrections using the adjustment nuts at the
inlet precision leveling foot.