MSD
TM
Series
© Copyright 2018 Fluid Equipment Development Company | www.fedco-usa.com
-
26
-
Figure 39 - Remove Coupling Guards
5. Loosen screws and remove the two coupling
guards. This allows better access to view
the coupling alignment.
Figure 38 - Check Flex Coupling Fit On Shaft
4.
Inspect the flexible coupling radial and axial
fit. It should be tight with no visible radial
movement and slide smoothly on and off
the motor shaft.
Pump Assembly Continued
NO
MOVEMENT
NO
MOVEMENT
NO
MOVEMENT
NO
MOVEMENT
SMOOTH MOVEMENT