FEASA LED ANALYSER
FUNCTIONAL VERSION
User Calibration Mode
getXOFFSET##
- Return the x Chromaticity offset
Transmit
Receive
getxoffset##
±
0.xxx
Where:
##
represents the Fiber Number and is a number in the range 01 – 20.
±0.xxx
represents the x Chromaticity offset
Description
This command is used to return the x Chromaticity offset for the LED under the Fiber number
##. The value of this offset must be set by the
setxoffset##
command. The default value
is 0.000.
Example:
The PC transmits
getxoffset01
to the LED Analyser to instruct it to send the stored x
Chromaticity offset for the LED positioned under Fiber No 1. The LED Analyser will return a
string
±0.xxx
to the PC.
getxoffset01
+0.155