FCAR FD505 Wheel Alignment System User Manual
37
4) If the measurement is successful, the system will automatically pop up the
measurement results, as shown in the figure:
Figure 4.2.3-5 Backward measurement results
In order to make the user more directly understand the condition of the vehicle, the
result display interface uses different color fonts to indicate whether the current measured
value is within the standard range:
Red font: measured value beyond the standard range
Green font: measured value within the standard range
Black font: current measured value without reference range
4.3
Lift mode
General measurement procedure for lift mode
:
Model selection Lift the vehicle
/
push compensation adjust back tilt measurement adjust Test drive Save
measurement data View/print results
,
The following describes the operation flow and
method of the lift mode.
Note: Before the cart is measured, the steering wheel must be level and locked