![Fbt VAIE 2000 Operating Manual Download Page 56](http://html1.mh-extra.com/html/fbt/vaie-2000/vaie-2000_operating-manual_3695782056.webp)
VAIE 2000 | Voice Alarm Integrated Systems
System Manual | 2013
UK
11
VAC 2006 • VAR 2006
tECHnICAL SPECIFICAtIonS
VAC 2006
Display
3”, backlit, 128x64 dots
Inputs
uSB-EXt.
Powered uSB input on the front panel - type A socket
Emergency microphone
• Sensitivity / Impedance
• Frequency response / S/N ratio
Balanced XLR-F on the front panel
Signa level 20 mV / 10 k
W
60 ÷ 20.000 Hz / 72 dB
In.1
Socket (MIC.)
• Sensitivity / Impedance
• Frequency response / S/N ratio
Programmable for the following modes: on / oFF / Precedence / VoX with A.P.t.
Balanced XLR-F (with possibility of activating 24 V phantom power supply
Signal level Min. 3 mV - Max 100 mV / 1,8 k
W
240 ÷ 20.000 Hz / 63 dB
In.2
Socket (MIC.)
• Sensitivity / Impedance
• Frequency response / S/N ratio
Socket (LInE)
• Sensitivity / Impedance
• Frequency response / S/N ratio
Programmable for following modes: on/ oFF / Precedence / VoX with A.P.t.
Balanced XLR-F (with possibility of activating 24 V phantom power supply)
Signal level Min. 3 mV - Max 100 mV / 1,8 k
W
240 ÷ 20.000 Hz / 63 dB
Balanced with terminals(HOT-COM-GND)
Max signal level 1800 mV / 31 k
W
60 ÷ 20.000 Hz / 84 dB
AuX
• Sensitivity / Impedance
• Frequency response / S/N ratio
RCA stereo socket for source of sound (BGM) – Conversion to mono
Max signal level 1800 mV / 31 k
W
60 ÷ 20.000 Hz / 84 dB
Paging units
• Sensitivity / Impedance
• Frequency response / S/N ratio
2 Rj45 for calling (PA) units of the MBt 1106 / MBt 1112 range.
Max signal level 1400 mV / 85 k
W
60 ÷ 20.000 Hz / 83 dB
EMERGEnCY unItS
Rj45 for connection to a dedicated emergency microphone station.
outputs
SLAVE LInK outPut
• Output level / Impedance
Rj45 for connection to an VAR 2006 / dPu / VAIE 2250 unit
Max 2000 mV / 400
W
VAC 2006 LInK
• Output level / Impedance
• Sensitivity / Input impedance
Rj45 for connection to a VAC 2006 unit
Max 2000 mV / 400
W
2000 mV / 50 k
W
Emergency controls
• CONTROL INPUTS inputs
• CONTROL OUTPUTS outputs
Programmable as normally Activated or normally de-activated.
7 inputs with diagnostics.
3 relays for signalling emergency conditions and failures, NO-NC-Changeover terminals.
Precedence In 1 - In 2
Precedence input with terminals with 12 V
dc
.
LAn
Presa LAn Rj45 per collegamento tCP/IP a web server.
overall
Mains power supply @230V
ac
Consumption @230V
ac
230 Vca 50/60 Hz ±10%
10 W
External power supply @24V
dc
Consumption @24V
dc
24 Vcc (min 22Vcc ÷ max 28Vcc)
0,3 A
Environmental operating conditions
Temperature: +5°C to +40°C / Relative humidity: 25% to 75% non-condensing
Mounting
Direct to rack 19” (2U).
Size of unit (L x H x D)
Size of package (L x H x D)
482 x 88 x 220 mm
522 x 155 x 292 mm
Net weight
Gross weight
4,5 kg
5,5 kg
tECHnICAL SPECIFICAtIonS
VAR 2006
Mains power supply @230V
ac
Consumption @230V
ac
230 Vca 50/60 Hz ±10%
12 W
External power supply @24V
dc
Consumption @24V
dc
24 Vcc
0,5 A
Maximum switchable output power per single zone
500 W
Environmental operating conditions
Temperature: +5°C to +40°C / Relative humidity: 25% to 75% non-condensing
Mounting
Direct to rack 19” (1U)
Size of unit (L x H x D)
Size of package (L x H x D)
482 x 44 x 220 mm
522 x 155 x 292 mm
Net weight
Gross weight
4 kg
5 kg