7.
Inhalation treatment method and precautions
To take an inhalation treatment, sit upright and relax, in any case stay quiet, and do not walk around because this
would cause a constriction of the airways, which would impair the effectiveness of the inhalation treatment.
If you are bed-ridden, use pillows to sustain yourself so as to sit as upright as possible.
In case of outdoor treatments or in special environments, take great care to keep airways as patent (open) as
possible.
Generally a single treatment shall not exceed 15 minutes. Consult your physician with regard to the correct
treatment time. In case of child treatment, closely comply with the physician’s instructions.
During the treatment, stay calm and relaxed. Take slow and deep breaths, so that the medication can reach the
deep and fine bronchial tubes. Hold your breath for a few seconds, then breath out slowly to allow the medication
to be better absorbed and the treatment to be more effective. After the nebulizing treatment, breath in fresh air.
After each treatment, always throw away any residual medication.
8.
Safety measures
After unpacking the nebulizer, make sure there are no visible damages or defects. In particular, check that there are
no cracks in the casing. In case of cracks, or if in doubt, contact directly your authorized dealer.
Use the nebulizer only for its intended use, that is, inhalation treatment. Any other use is improper and as such
dangerous. The manufacturer shall not be held liable for any risk or damage caused by an improper or incorrect use.
The unit is not water-tight, therefore do not dip the nebulizer in the water to clean it. If by accident it falls into the
water, it must be handed over to engineers for the necessary controls.
Do not use the unit in the presence of anesthetic mixtures or other flammable mixtures when in contact with air,
oxygen or nitrous oxide.
In case of damages to any of the accessories of the nebulizer, or if the device does not work regularly, stop using it.
Any repair or replacement of parts of the nebulizer should be carried out by authorized dealers, and only original
spare parts should be used.
The AC power supply device provided with the nebulizer should be used with this unit only. It is forbidden to use
this device for other purposes or use a device having other specifications with this unit. The manufacturer shall not
be held liable for any consequences from an incorrect or improper use. In case the AC power supply device does not
work, contact the authorized dealer to obtain the original AC power supply of the same type and size.
9.
Troubleshooting
In case the nebulizer fails to nebulize, or the nebulization is too weak, check the following:
Make sure the power supply is correct in terms of voltage and frequency required by the unit, and check that the
power plugging and wiring is appropriate.
Make sure the air tube is not clogged and that the various accessories are correctly connected.
Make sure the wafer on the bottom of the water tank shows no rust or dirt. If it shows a strong discoloration, replace
it before using the nebulizer.
Should the malfunction persist despite everything appears to be normal, send the nebulizer to the authorized dealer
for repairing.