background image

W

 WARNING

This respirator helps protect against certain airborne contaminants. 

Misuse may result in 

sickness or death.

 For proper use, see your supervisor, or 

User Instructions

 or call 3M in U.S.A. 

FOREWARD

These 

User Instructions

 provide information about facepiece use only. Important information is provided in the 

User 

Instructions

 with each of the air fi ltration systems that are used with 3M™ Full Facepiece FF-401, FF-402 and FF-403. 

Read all 

User Instructions

 and warnings before using. Keep these 

User Instructions

 for reference. If you have questions 

regarding these products contact 3M Technical Service. 

Intended Use

The 3M™ Ultimate FX Full Facepiece FF-400 Series Respirators (FF-401, FF-402 and FF-403) are designed to help 
provide respiratory protection against certain airborne contaminants when used in accordance with all use instructions 
and limitations and applicable safety and health regulations. All FF-400 series facepieces meet the impact requirements 
of the ANSI Z87.1-2003 standard, high impact level, for limited face and eye protection. 

W

 WARNING

Properly selected, used, and maintained respirators help protect against certain contaminants by 
reducing airborne concentrations below the Occupational Exposure Limit (OEL). It is essential to 
follow all instructions and government regulations on the use of this product, including wearing 
the complete respirator system during all times of exposure in order for the product to help protect 
the wearer.

Misuse of respirators may result in overexposure to contaminants and lead to 

sickness or death.

 For proper use, see supervisor, refer to the product 

User Instructions

 or contact 

3M Technical Service.

List of Warnings and Cautions within these 

User Instructions

W

 WARNING

Failure to follow these instructions may reduce respirator performance, expose you to contaminants 
above the OEL, and 

may result in sickness or death.

•  To help maintain a good seal between the face and the faceseal, the respirator faceseal must 

be clear of obstructions at all times. Do not use with beards or facial hair that prevent direct
contact between the face and the respirator faceseal. Do not use with corrective eyeglasses. If
corrective eyeglasses are required, a 3M™ Spectacle Kit must be used inside the respirator.

•  Do not clean respirator with solvents. Cleaning with solvents may degrade some respirator

components and reduce respirator effectiveness.

•  Inspect all respirator components before each use to ensure proper operating condition.
•  Do not alter, misuse, or abuse this respirator.

3

Ultimate FX Full Facepiece Reusable Respirator

User Instructions

 for 3M™ Ultimate FX Full Facepiece FF-401, Small, 3M™ Ultimate FX Full Facepiece FF-402, Medium, 

3M™ Ultimate FX Full Facepiece FF-403, Large

IMPORTANT: 

Before use, the wearer must read and understand these 

User Instructions

. Keep these instructions for 

reference.

This respirator has dual approval as a United States (US) National Institute for Occupational Safety and Health 
(NIOSH) full facepiece respirator and as Brazil Ministry of Labor full face piece respirator. 
Standard specifi c information is provided where applicable. All other information is common to both standards.

CAUTION

Failure to properly dispose of spent cartridges, fi lters, or respirators contaminated by hazardous materials can result in 
personal exposures as well as environmental harm. Handling, transportation and disposal of spent cartridges, fi lters, 
or respirators must comply with all applicable federal, state, provincial, and local laws and regulations.

NIOSH Cautions and Limitations for Negative Pressure Usage

The following restrictions may apply. See NIOSH Approval Label. If you are using the FF-400 series facepiece as part of 
a Supplied Air Respirator configuration, refer to the 

User Instructions

 that accompanies your air control device for 

information on NIOSH Cautions and Limitations. 
A -  Not for use in atmospheres containing less than 19.5 percent oxygen.
B -  Not for use in atmospheres immediately dangerous to life or health.
C -  Do not exceed maximum use concentrations established by regulatory standards.
H -  Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters 

are replaced before breakthrough occurs.

J -  Failure to properly use and maintain this product could result in injury or death.
L -  Follow the manufacturer’s 

User’s Instructions

 for changing cartridges, canister and/or fi lters.

M -  All approved respirators shall be selected, fi tted,  used, and maintained in accordance with MSHA, OSHA, and other 

applicable regulations.

N -  Never substitute, modify, add, or omit parts. Use only exact replacement parts in the confi guration as specifi  ed by 

the manufacturer.

O -  Refer to 

User’s Instructions

, and/or maintenance manuals for information on use and maintenance of these 

respirators.

P -  NIOSH does not evaluate respirators for use as surgical masks.
S -  Special or critical 

User’s Instructions

 and/or specifi c use limitations apply. Refer to 

User’s Instructions

 before 

donning.

S - Special or Critical 

User’s Instructions

3M™ Organic Vapor Service Life Indicator Cartridges (6001i and 60921i) and Mercury Vapor Cartridges (6009S and 
60929S) are equipped with a passive 3M™ End of Service Life Indicator (ESLI).

 

The indicator must be readily seen 

when wearing the respirator without manipulation. If you cannot readily see the ESLI, use a mirror to observe the ESLI, 
rely on a co-worker who can see the ESLI, or go to a clean area, remove the respirator and view the ESLI. Do not rely 
solely on the organic vapor ESLI unless your employer has determined that it is appropriate for your workplace. See 
6001i 
or 60921i 

User Instructions

 for more information, including 

Special Instructions

 regarding the ESLI.

 

The mercury vapor 

cartridges must be discarded when the ESLI changes to the discard color found on the mercury vapor cartridge label; or 
within 30 days of opening packaging; or when ESLI becomes dirty or damaged; or when odors of vapors or gases 
become noticeable; or according to chlorine service life; whichever occurs fi rst.  Mercury vapor has no odor.

Respirator Program Management

Occupational use of respirators must be in compliance with applicable health and safety standards. By law U.S. 
employers must establish a written respiratory protection program meeting the requirements of the OSHA Respiratory 
Protection Standard 29 CFR 1910.134 and any applicable OSHA substance specifi c standards. In Canada, CSA standard 
Z94.4 requirements must be met and/or requirements of the applicable jurisdiction, as appropriate. In Brazil, follow the 
Respiratory Protection Program of the Ministry of Labor.

For additional information on this standard contact OSHA. Consult an industrial hygienist or call 3M Technical Service 
with questions concerning applicability of these products to your job requirements.

Table 1: Major Sections of OSHA 29 CFR 1910.134

Section

Description

A

Permissible Practice

B

Defi nitions

C

Respiratory Protection Devices

D

Selection of Respirators

E

Medical Evaluations

F

Fit Testing

G

Use of Respirators

H

Maintenance and Care of Respirators

I

Breathing Air Quality and Use

J

Identifi cation of Cartridges, Filters, and Canisters

K

Training and Information

L

Program Evaluation

M

Recordkeeping

Assigned Protection Factors

Table 2: Assigned Protection Factors

Type of Respirator

APF

Full Facepiece Negative Pressure Air Purifying Respirator

10/50

1

Full Facepiece Supplied Air Respirator (SAR) Continuous Flow

1000

1

 The respirator wearer must be fi t tested using a quantitative fi t test method in order to use an assigned protection 

factor greater than 10 when used as a negative pressure air purifying reespirator.

In Brazil, according to the Respiratory Protection Program of the Ministry of Labor, do not use full face piece respirator 
when concentrations of contaminants are greater than 100 times the permissible exposure limit in air-purifying mode.

OPERATING INSTRUCTIONS

Unpacking

Inspect the package contents for shipping damage and ensure all components are present (Refer to Fig. 27). The product 
should be inspected before each use following the procedures in the 

Inspection

 section of this 

User Instruction

Summary of Contents for Ultimate FX FF-401

Page 1: ... dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards H Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s User s Instructions for...

Page 2: ...r the respirator on the face and to tighten the straps twice following steps 4 5 6 first to snug the respirator then repeating steps 4 5 6 a second time to secure the facepiece seal Care must be taken to not over tighten bottom straps on the first turn 1 Fully loosen all six headstraps 2 Hold the front of the facepiece with one hand and the straps comfort cradle away from the facepiece with the ot...

Page 3: ...on valve cover and examine exhalation valve and valve seat for signs of dirt distortion cracking or tearing Replace exhalation valve cover 6 Inspect lens for any damage that may impair respirator performance or vision Cleaning and Storage Cleaning is recommended after each use 1 Remove cartridges filters and or breathing tubes and nose cup The exhalation valve cover exhalation valve assembly speak...

Page 4: ...n ports These valves should be inspected before each respirator use and replaced whenever valves become damaged or lost 1 Remove existing valve s by grasping valve and pulling valve stem out from valve seat 2 Install new valve s onto valve seat s by pushing through valve stem seat s Be certain valve stem s is fully engaged through valve seat s lays flat and moves freely spins Head Harness Assembly...

Page 5: ...7 Fig 5 Fig 18 Fig 6 Fig 19 Fig 7 Fig 20 Fig 8 Fig 21 Fig 9 Fig 22 Fig 10 Fig 23 Fig 11 Fig 24 Fig 12 Fig 25 Fig 27 FIG 13 Fig 26 Fig 28 1 1 2 2 Fig 15 Looking for dependable masks and respirators Rely on 3M for quality and long lasting products ...

Reviews: