FAURE-HERMAN
COMPONENT MAINTENANCE MANUAL
744-082 / 744-082-3
28-49-91
PAGE 119/120
MAR 31/07
No
PC board Z3
defective
Replace
PC board
Yes
Checking the spare
indicator light function
Remaining
flight time
decreases
No
Yes
PC board Z2
defective
Replace
PC board
Indicator
light comes when
time = 40 min.
PC board Z2
defective
Replace
PC board
Yes
Remaining
flight time
increases
No
Indicator
light goes out when
time = 46 min.
PC board Z2
defective
Replace
PC board
No
PC board Z2
defective
Replace
PC board
PC board Z3
defective
Replace
PC board
The document reference is online, please check the correspondence between the online documentation and the printed version.