2-22
I/O Setting Screen
2-6-10 On delay
Sets the time from when the measured value exceeds the threshold until the output actually turns ON.
Cancelling output until this time has elapsed prevents the control input/output from turning ON/OFF
repeatedly in a short time (chattering).
Example:
ON
OFF
(2)
(1)
Upper
limit
Measurement value
Shorter than the specified time
(1) When the measured value remains below the threshold from when the measured value falls below the
threshold until after the On delay time has elapsed
Ö
Output turns ON.
(2) When the measured value is equal to or more than the threshold from when the measured value falls
below the threshold until after the On delay time has elapsed
Ö
Output remains OFF. (The output does not turn ON.)
,QSXWUDQJH WR>PVHF@
Default value: 0