2-15
1
2
W
eb Settings Screen and Function Details
Measurement Screen
2-5-14 Edge measurement
&RPSDUHVWKHFXUUHQWO\PHDVXUHGYDOXHZLWKWKHPHDVXUHGYDOXHSULRUWRWKHVSHFL¿HGVDPSOLQJFRXQW
This allows gradual changes to be ignored for detection while measuring extreme height differences.
This function will not be used when set to “0.”
:KHQXVLQJWKLVIXQFWLRQPHGLDQ¿OWHUVDQGWKHFRXQWIRUSHUIRUPLQJPRYLQJDYHUDJHDUHLJQRUHG
Input range: 0 to 100,000 (Number of samplings)
Default value: 0 (Number of samplings)
2-5-15 Hold
([WUDFWVWKHVSHFL¿HGYDOXHVXFKDVWKHPD[LPXPRUPLQLPXPZLWKLQDVHWSHULRG
The value used for “Hold set” is used as the hold period. Use this function after inputting the hold reset when
using auto peak or auto bottom.
OFF: When the hold function is “OFF,” the measurement result is output as is and hold input is ignored.
ON
OFF
Measurement
value
Hold
3HDN7KHPD[LPXPYDOXHGXULQJWKHVDPSOLQJSHULRGVHH¿JXUHEHORZZLOOEHRXWSXW
ON
OFF
Measurement
value
Hold
Sampling period
Internal measurement value
Peak hold measurement value