Hardware Information
To view the RAID subsystem controller’s hardware monitor information, press
ENT
to enter the main menu. Press
UP/DOWN
to select the
Hardware
Information
option, and then press
ENT
. All hardware information will be
displayed. Press
UP/DOWN
to browse all the hardware information.
The Hardware Monitor Information provides the temperature, fan speed
(chassis fan) and voltage of the internal RAID subsystem. The temperature
items list the current states of the controller board and backplane. All items are
also unchangeable. The warning messages will indicate through the, LED and
alarm buzzer.
Item Warning
Condition
•
Controller
Board
Temperature
> 60 Celsius
Backplane Temperature
> 60 Celsius
Controller Fan Speed
< 1900 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.3V
Power 3.3V
< 3.0V or > 3.6V
CPU Core V1.5V