![Fastech Ezi-Step Plus-R User Manual Download Page 58](http://html1.mh-extra.com/html/fastech/ezi-step-plus-r/ezi-step-plus-r_user-manual_546246058.webp)
www.fastech.co.kr
58
13. Parameter
13.3 Parameter Description
No.
Description
Unit
Lower
Limit
Upper
Limit
Default
0
Pulse per Revolution
:
Number of pulses per revolution.
Vaule
ppr
Vaule
ppr
0
500
8
6400
1
1000
9
8000
2
1600
10
10000
3
2000
11
20000
4
3200
12
25000
5
3600
13
36000
6
4000
14
40000
7
5000
15
50000
0
15
10
1
Axis Max Speed :
When position moving commands (absolute move, incremental move) are
given, this mode sets the maximum speed which the motor can
operate. So, the motor cannot be operated faster than this value
in any case. This value is set to [pps] unit.
pps
1
500,000
500,000
2
Axis Start Speed :
When position moving commands (absolute move, incremental move) are
given, this mode sets the operation start speed to [pps] unit.
pps
1
35,000
1
3
Axis Acc Time :
When position moving commands (absolute move, incremental move) are
given, this mode sets the acceleration section of operation start
segment to [msec] unit.
Possible range is different from
Axis Speed
.
(Ex.1) Axis Start Speed=1, Move Speed=400000 : 1~1430 [msec]
(Ex.2) Axis Start Speed=1, Move Speed=10000 : 1~350 [msec]
msec
1
9,999
100
4
Axis Dec Time :
When position moving commands (absolute move, incremental move) are
given, this mode sets the deceleration sect ion of operation stop
segment to [msec] unit.
Possible range is different from
Axis Speed
same as ‘Axis Acc
Time’parameter
msec
1
9,999
100
5
Speed Override :
When position moving commands (absolute move, incremental move) are
given, the operation speed i s subject to the rat io set to ‘Move
Speed’. (Ex) If current move speed is 10,000 and speed override
is 200, actual motion speed is set to 20,000.
%
1
500
100
6
Jog Speed :
When jog position moving command is given, this mode sets the
motor revolution valu e to [pps] unit.
pps
1
500,000
5000
7
Jog Start Speed :
When jog position moving command is given, this mode sets the
operation start speed to [pps] unit.
pps
1
35,000
1
8
Jog Acc Dec Time :
In case of jog operation, this mode sets the time of accelerati on
and deceleration sections to [msec] unit.
msec
1
9,999
100
9
Alarm Logic :
When the motor or the drive is defective and so alarm signal
output is ON through CN1 connector, this mode sets the output
signal level.
♦ 0 : 0 V (Active low level)
♦ 1 : 24V (Active high level)
0
1
0
Summary of Contents for Ezi-Step Plus-R
Page 1: ...User Manual Text Rev 08 05 028 ...
Page 8: ...www fastech co kr 8 1 Safety Precautions 2 Ezi STEP PR MI ...
Page 9: ...www fastech co kr 9 1 Safety Precautions 2 2 Dimensions 1 Ezi STEP PR 2 Ezi STEP PR MI ...
Page 20: ...www fastech co kr 20 5 Configuration of the Controller 3 Configuration of Ezi STEP PR MI ...
Page 22: ...www fastech co kr 22 5 Configuration of the Controller 2 Diagram of Ezi STEP PR86 ...
Page 23: ...www fastech co kr 23 5 Configuration of the Controller 3 Diagram of Ezi STEP PR MI ...
Page 67: ...www fastech co kr 67 Appendix Connector for cabling ...
Page 69: ...www fastech co kr 69 Appendix ...