www.fastech.co.kr
52
11. Communication Function
11. Communication Function
In case of RS-485, up to 16 axes can be controlled by the multi -drop link(daisy chain).
If Windows goes to the stand -by mode, serial communication is
basically disconnected. So, after recovering from the stand -by mode,
the user should connect communication again. This content is equally
applied to the library provided with the product.
11.1 Connection with the PC
There are one method of connecting the drive and the PC by RS-485(serial
communication). PC’s RS-232C port is used. By using following communication
converters according to each communication type, the user can connect the PC and the
drive module. The maximum communication speed i s 115200[bps] with RS -232 to RS-485
converter.
For connection with the PC, refer to
「5.2 Controller Configuration」
.
1)
Cable of Connecting RS232 Port (to PC) and Converter (RS232 ↔ RS-485)
Normally Power does not need to be supplied to the converter module. But when
the communication have problems without power, DC 5~24V external power can connect.
The signal is wired as follows.
RS-485 Converter (to RS -232)
Caution
Summary of Contents for Ezi-Step Plus-R
Page 1: ...User Manual Text Rev 08 05 028 ...
Page 8: ...www fastech co kr 8 1 Safety Precautions 2 Ezi STEP PR MI ...
Page 9: ...www fastech co kr 9 1 Safety Precautions 2 2 Dimensions 1 Ezi STEP PR 2 Ezi STEP PR MI ...
Page 20: ...www fastech co kr 20 5 Configuration of the Controller 3 Configuration of Ezi STEP PR MI ...
Page 22: ...www fastech co kr 22 5 Configuration of the Controller 2 Diagram of Ezi STEP PR86 ...
Page 23: ...www fastech co kr 23 5 Configuration of the Controller 3 Diagram of Ezi STEP PR MI ...
Page 67: ...www fastech co kr 67 Appendix Connector for cabling ...
Page 69: ...www fastech co kr 69 Appendix ...