8. Control I/O Signal
PT No.
Position Value [pulse] of Corresponding PT
3
12010
4
15300
12
-12800
255
38520
*
After executing Teaching, click ‘Refresh’ icon, and the position value will
be displayed to the position table.
*
Click ‘Save to ROM’ icon, and the position value will be saved to the ROM
area.
*
Teaching signal can be used by two methods; the user assigns actual signal to
the motor, or he clicks ‘Teaching’ icon at the ‘I/O Monitoring’ window of
User Program(GUI).
11)
E-Stop Input
When ‘Emergency stop’ signal is set to ON, th e current motion is stopped
immediately without deceleration. E -Stop signal is active in ON level and pulse
scale is 10ms or more.
Motion Pattern
Emr Stop Input