9. KEYBOARD
①
③
⑤
⑦
⑧
②
④
⑥
⑨
⑩
①
= “LINE“ Green Led = ON = Presence of power supply (230V; 115V; 100V)
②
= T1 Button = Press it to start shaking cycle T1 (1 minute by default)
③
= T1 Red Led = ON = T1 shaking cycle activated
④
= T2 Button = Press it to start shaking cycle T2 (2 minutes by default)
⑤
= T2 Red Led = ON = T2 shaking cycle activated
⑥
= T3 Button = Press it to start shaking cycle T3 (3 minutes by default)
⑦
= T3 Red Led = ON = T3 shaking cycle activated
⑧
= “CLAMP OK” Green Led = ON = Machine is clamping the can
⑨
= Button Stop/Up = Stop shaking / open plate (Reset after emergency stop)
⑩
= Emergency button
10. HOW TO OPERATE
10.1. SWITCHING SO300 ON
When the machine is off, the door is locked.
Check that the emergency button (10) is not pressed in; if it is, turn it 90° clockwise.
Switch SO300 on simply plugging it in the mains socket. The green led “LINE” (1) will turn on.
If the upper (moving) plate is not in the ‘completely open’ position, it will automatically unclamp.
10.2. PLACING THE CAN
Open the door and place the can in the centre of the lower plate; then close the door.