1. INTRODUCTION 

 

SO300  by  FAST  &  FLUID  MANAGEMENT  is  the  result  of  the  most  recent technology  in  high  speed  paint 
mixing. Your SO300 by FAST & FLUID MANAGEMENT is a sturdy and effective shaker; its way of operating 
and its design show all quality of a careful engineering work on the product. 

To appreciate fully and protect your investment, we suggest that you take some time to read this manual. 

As usual, FAST & FLUID MANAGEMENTwill support you post sales assistance service. 

The few maintenance operations, which will be mentioned further on, shall be carried out regularly. 

 

 

FAST &  FLUID  MANAGEMENT will  not  be  held  responsible  for  any  damage  or accident 
which  might  happen  because  of  failure  to  respect  the  regulations  set,  or  because  of 
wrong  use  or  of  maintenance  carried  out  without  the  standard  safety  rules 

being 

followed, as explained further on.

 

 

 

 

SO300 shaker must not be switched on if it has not been earthed through one or both the 

earthing connection points (socket and/or earthing bolt). 

 

 

 

 

2. INTELLECTUAL PROPERTY RIGHTS 

 

 

Statement on Intellectual Property Rights. 
The information contained in this manual is based on data which belong to FAST & FLUID MANAGEMENT. 
This manual has been drawn up expressly for assistance in the use and general maintenance of SO300 shaker. 
The publication of this info does not give any allowance for reproducing or using this manual for other than installation, use 
or maintenance. 
No part of this manual can be reproduced, translated or filed (neither on computer) in any form or by any means without 
written authorization by a FAST & FLUID  MANAGEMENT officer. 

 

 

 

3. TECNICHAL SPECIFICATIONS 

 

EN 292 Part 1 and 2: 1991 

Safety of machinery - Fundamentals, general principles for design 

EN 418: 1992    

 

Safety of machinery – Emergency stop equipment, functional aspects 

EN 60204 Part 1: 1997   

Safety of machinery – Electrical equipment of machines  - specifications on general aspects . 

EN 954 – 1: 1996 

 

Safety of machinery – Safety of parts of the control system – Part 1: general principles for design 

EN 1088: 1995   

 

Safety of machinery  

EN 294: 1992   

 

Safety of machinery – Safety distance to avoid damages in areas of the machines that are reachable by 
upper limbs. 

EN 953: 1997   

 

Safety  of  machinery  -  Protections  –  Requirements  on  design  and  construction  of  mobile  and/or  fixed 
protections. 

PrEN 12757-1   

 

Mixing/shaking machines for coating products; 

 
EN 61000-6-3 Parte 6-3 2001  
EN 61000-6-1 2001 

 

 

EN 61000-3-2 2000 

 

 

EN 61000-3-3 1995+A1 2001  
Electromagnetic Compatibility Directiv (EMC) – Part 3: Limits – Section 2:  
 
Maximum noise level :   

 

< 70 dB 

Shaking speed (motor revolutions): 

= 685 rpm 

Machine dimensions:   

 

72cm (Width), 116cm (Height), 69cm (Depth), 210Kg (Weight) 

Maximum can weight:   

 

35 kg 

Maximum can dimensions: 

 

HxWxD 440x350x350 mm. Within the limits, also squared and oval cans can be shaked. 

Minimum cans height:   

 

65 mm 

Timer: 

 

 

 

Electronic, programmable 

Power supply:   

 

 

0.75 kiwi 230V 50Hz 

 

 

 

 

0.75 kiwi 115V 60Hz

 

 

Summary of Contents for SO-300

Page 1: ...nit of Idex Corporation Shaker SO 300 USER MANUAL FAST FLUID MANAGEMENT Srl A Unit of IDEX Corporation Via Pelizza da Volpedo n 109 111 20092 Cinisello Balsamo MI ITALY Tel 39 02 66091 1 Fax 39 02 660...

Page 2: ...ARRANTY TERMS AND CONDITIONS 3 5 GENERAL DESCRIPTION 3 6 SAFETY RULES 3 7 RESIDUAL RISKS 5 8 INSTALLATION REQUIREMENTS 6 9 KEYBOARD 7 10 HOW TO OPERATE 7 11 LOADING THE CAN INTO THE MACHINE 8 12 ACOUS...

Page 3: ...not give any allowance for reproducing or using this manual for other than installation use or maintenance No part of this manual can be reproduced translated or filed neither on computer in any form...

Page 4: ...ts to the machine without written approval and or by unauthorized staff in case of incomplete maintenance or failure to observe the instructions contained in this manual The above conditions are appli...

Page 5: ...SO300 tools after servicing 5 Make sure the environment in which the machine is installed complies with the laws in force you need to have an authorization issued by the Fire Brigade or by the compete...

Page 6: ...tection protective glasses protective shoes protective gloves especially during the loading and unloading of the cans 7 4 General danger situations There is not any particular hazardous situation e g...

Page 7: ...tal conditions must be within the following limits Air temperature 10 to 40 C Relative humidity 30 to 90 During the installation it is advisable to use protective gloves to avoid injuries Connect the...

Page 8: ...T3 shaking cycle activated CLAMP OK Green Led ON Machine is clamping the can Button Stop Up Stop shaking open plate Reset after emergency stop Emergency button 10 HOW TO OPERATE 10 1 SWITCHING SO300 O...

Page 9: ...efault Also these 3 parameters have been pre set in the testing phase in the factory in any case they can be modified by a technician through the Operator Panel according to the needs requirement of t...

Page 10: ...sor activated Stand by No precaution Door closed 14 MAINTENANCE AND CLEANING During maintenance and check operations please wear protection gloves and unplug the machine These operations must be carri...

Page 11: ...se any non abrasive cleaning product for domestic use on washable surfaces Control panel keyboard Use a wet cloth The use of neutral soap is allowed Then wipe no rinse with a dry cloth or a paper towe...

Page 12: ...ttons T1 T2 T3 Before the shaking starts press Stop Up Open the door Unplug the machine from the mains Remove the grease and possible dried paint see paragraph 12 3 Then put some grease with a brush o...

Page 13: ...anel board Uni directional AC motor drive Shaker motor Digital inputs Can sensors DC Solenoid drive Door solenoid Logic board Bi directional Pwm motor drive Clamp motor Digital inputs Upper limit swit...

Page 14: ...1 P O Box 220 2170AE SASSENHEIM 1 01 Revnr Sheet Title Date Drawn Remarks Filename FAST FLUID MANAGEMENT Version RED GREEN 1 3 BROWN WHITE BROWN BLUE BROWN BLUE 1 2 BROWN WHITE 1 BLUE BROWN 20V GREY 0...

Page 15: ...FAST FLUID MANAGEMENT srl A Unit of Idex Corporation 14...

Reviews: