EMERGENCY BUTTON (when the machine is shaking) 
 

 

 

 

Switch SO300 on 

(just plug it in) 

 

Open the door, load 

a can and close the 
door. 

 

Press one of the start 

buttons (T1, T2, T3) to 
start the shaking cycle. 

 

 

Before the end of the 

shaking cycle, press the 
emergency button 

 

Shaking shall stop and a 

warning noise shall be 
heard. 

 

The shaking cradle shall 

stop and the upper plate shall 
not unclamp. 

 

The can shall be trapped in 

the cradle and no button shall 
work. 

 

De-activate emergency 

button by turning it 
clockwise. 

 

Press all buttons 

(Stop/Up excluded). None 
of them shall work 

 

Press Stop/up button. 

Make sure the upper plate 
unclamps 

 

Check the door: it shall 

be unlocked. 

14.3. Cleaning 

 

All cleaning operations must be operated with the machine unplugged. 
For inner parts cleaning, before unplugging the machine, open the door.

 

 

Body (panels) and door 

Use any non abrasive cleaning product for domestic use on washable surfaces. 

 

Control panel (keyboard) 

Use a wet cloth. The use of neutral soap is allowed. Then wipe (no rinse) with a dry cloth or a paper towel. 

 

Inner parts of the body 

In case of paint loss, clean immediately! 
Dried paint can be removed with a broad knife. Then Use any non abrasive cleaning product for domestic 
use on washable surfaces. 

 

Inner parts (shaking cradle) 

 

 

 

In case of paint loss, clean immediately! 

 

Dried paint can be removed with a 

broad knife. 

 

To clean lubricated parts, just use a 

cloth, which will remove the paint 

together with the lubricant. 

 

Immediately restore the lubrication as 

per further instructions 

 

Accidental paint leakages/losses inside and/or outside the SO300 

 
Immediately clean the machine and the floor of the ‘user area’ to avoid slipping risks. 

Do not use water jets or high pressure cleaners to clean SO300. 
Do not use solvents to clean SO300 

In case solvents are absolutely necessary, after using them keep the machine disconnected from the mains 
and its door completely open for at least 1 hour. 
 

Summary of Contents for SO-300

Page 1: ...nit of Idex Corporation Shaker SO 300 USER MANUAL FAST FLUID MANAGEMENT Srl A Unit of IDEX Corporation Via Pelizza da Volpedo n 109 111 20092 Cinisello Balsamo MI ITALY Tel 39 02 66091 1 Fax 39 02 660...

Page 2: ...ARRANTY TERMS AND CONDITIONS 3 5 GENERAL DESCRIPTION 3 6 SAFETY RULES 3 7 RESIDUAL RISKS 5 8 INSTALLATION REQUIREMENTS 6 9 KEYBOARD 7 10 HOW TO OPERATE 7 11 LOADING THE CAN INTO THE MACHINE 8 12 ACOUS...

Page 3: ...not give any allowance for reproducing or using this manual for other than installation use or maintenance No part of this manual can be reproduced translated or filed neither on computer in any form...

Page 4: ...ts to the machine without written approval and or by unauthorized staff in case of incomplete maintenance or failure to observe the instructions contained in this manual The above conditions are appli...

Page 5: ...SO300 tools after servicing 5 Make sure the environment in which the machine is installed complies with the laws in force you need to have an authorization issued by the Fire Brigade or by the compete...

Page 6: ...tection protective glasses protective shoes protective gloves especially during the loading and unloading of the cans 7 4 General danger situations There is not any particular hazardous situation e g...

Page 7: ...tal conditions must be within the following limits Air temperature 10 to 40 C Relative humidity 30 to 90 During the installation it is advisable to use protective gloves to avoid injuries Connect the...

Page 8: ...T3 shaking cycle activated CLAMP OK Green Led ON Machine is clamping the can Button Stop Up Stop shaking open plate Reset after emergency stop Emergency button 10 HOW TO OPERATE 10 1 SWITCHING SO300 O...

Page 9: ...efault Also these 3 parameters have been pre set in the testing phase in the factory in any case they can be modified by a technician through the Operator Panel according to the needs requirement of t...

Page 10: ...sor activated Stand by No precaution Door closed 14 MAINTENANCE AND CLEANING During maintenance and check operations please wear protection gloves and unplug the machine These operations must be carri...

Page 11: ...se any non abrasive cleaning product for domestic use on washable surfaces Control panel keyboard Use a wet cloth The use of neutral soap is allowed Then wipe no rinse with a dry cloth or a paper towe...

Page 12: ...ttons T1 T2 T3 Before the shaking starts press Stop Up Open the door Unplug the machine from the mains Remove the grease and possible dried paint see paragraph 12 3 Then put some grease with a brush o...

Page 13: ...anel board Uni directional AC motor drive Shaker motor Digital inputs Can sensors DC Solenoid drive Door solenoid Logic board Bi directional Pwm motor drive Clamp motor Digital inputs Upper limit swit...

Page 14: ...1 P O Box 220 2170AE SASSENHEIM 1 01 Revnr Sheet Title Date Drawn Remarks Filename FAST FLUID MANAGEMENT Version RED GREEN 1 3 BROWN WHITE BROWN BLUE BROWN BLUE 1 2 BROWN WHITE 1 BLUE BROWN 20V GREY 0...

Page 15: ...FAST FLUID MANAGEMENT srl A Unit of Idex Corporation 14...

Reviews: