FARMSCAN Jackal v2 General Description Manual Download Page 1

 
 

 

Summary of Contents for Jackal v2

Page 1: ......

Page 2: ...IZARD 15 AREA SPEED METER USING GPS SETUP WIZARD 20 TACHO RPM METER SETUP WIZARD 22 FLOW METER SETUP WIZARD 24 SLIPPAGE METER WIZARD 27 RATE METER SETUP SOLIDS GENERIC WIZARD 28 BATCH METER 30 RATE MONITOR 31 BIN LEVEL SENSOR 33 AIR VOLT DEPTH TEMP PRESSURE SENSOR 34 TRIPS EXPLAINED 37 ALARMS EXPLAINED 38 USER DEFINED SETUP OVERVIEW MANUAL 39 INPUTS MANUAL SETUP 40 FRONT SCREEN MANUAL SETUP 41 OTH...

Page 3: ...ods of machine operation that should not accumulate as a work total can be excluded from trip totals Our onboard calibration wizard makes setup a breeze It s simplified with the ability to enter either a factor pulses per unit or simply drive run a set amount whilst the unit is counting the pulses and let the system calculate its own factor Each input can be used to display information using imper...

Page 4: ...l 1 PARTS PICTORIAL MOUNTING INSTALLATION The Jackal is provided with a suction window mount Slide mount onto unit and push sideways to lock into place Make sure you hear a click of the mount locking into place Place in a convenient position on the windscreen and using the toggle lever pictured above Item 2 push all the way to the bottom until lever locks into position Note Monitor should be mount...

Page 5: ...eed Switch Alarm Hz A5 IN10 High Low On Off Full Empty I O B5 IN5 Prox Reed Switch Alarm Hz A6 IN9 High Low On Off Full Empty I O B6 IN6 Prox Reed Switch Alarm Hz A7 IN8 Varying volt sensor 0 5V B7 IN7 Varying volt sensor 0 5V A8 Not Used B8 Out1 solenoid shutoff pulse radar output Pulls to GND A9 Not Used B9 Out2 12V Supply Out Sensor GPS Power A10 RS232 Tx Transmit B10 BATT VE 12V Battery Termin...

Page 6: ...will have 3 wires such as flow sensors bin level sensors and pressure sensors FARMSCAN AG SENSOR COMPATABILITY CHART Farmscan Ag sensors that are compatible with the inputs are shown in the table below Sensor Options 1007P 2009 2034 1 Per Jackal 1501 2076 2077 1 Per Jackal A 2220P 2060 A 2080 AA 119 H L AA 114 AA 2010P AA 430 AA 123P AA 125 AA 242 AA 230 232 All styles AA 230A ALU AA 23A AL AA 230...

Page 7: ...105 x 1 AA 112P x 1 Input 1 B1 1501 Solenoid Shutdown Kit AH 488 x 1 AC 205 x 1 M F Packard s Output 1 B8 2076 Shaft sensor kit Slow speed 1 1500 rpm AA 110P x 1 AA 117 x 1 Input 2 6 B2 B6 2077 Shaft sensor kit High speed 100 9999 rpm 1 Per Jackal AA 112P x 1 AA 117 x 1 Input 1 B1 2202 Remote junction box kit Allows for all connections to Jackal via one simplified cable 2060 Bin Tank level sensor ...

Page 8: ...gnal wire A 2 wire sine wave flow sensor input can also be used found in the 2 AA 231 kit The diagram to the right shows which terminals to connect your sensors to If the ground earth A1 terminal already has a wire from another sensor applied to it then you will need to piggy back onto this wire NB There is only ONE 1 coil input on the Jackal Use the wizard to setup the port and calibrate a sensor...

Page 9: ... 2060 A 2220P These kits will all include an off off high low empty full style sensor The sensor is a 3 wire sensor and uses a ground earth wire a signal wire and a 12v power wire The diagram to the right shows which terminals to connect your sensors to If the ground earth A1 or regulated 12v power OUT2 B9 terminal already has a wire from another sensor applied to it then you will need to piggy ba...

Page 10: ... RUN HOLD Jackal version 2 above can connect an external run hold trigger wire into any unused port i e Jackal can be remotely placed on hold or run mode from an external source or switch without having to press the Run Hold button on the Jackal itself Please note that this is normally run through an automotive relay Ensure you are using the ground earth A1 terminal If the terminal already has a w...

Page 11: ...rminals are used for battery connection and the bare end used to connect to the rear Jackal Refer above image for power connection 3 Connect Ground to BATT VE Terminal B11 using the RED with BLACK stripe wire 4 Connect 12 Volts battery terminal to BATT VE Terminal B10 using the red wire 5 Ensure that the battery connection to the Jackal is 12 Volts Connecting 24V to the Jackal will VOID WARRANTY D...

Page 12: ...UN to signify that the monitor is active c When the monitor is in HOLD mode the unit displays the word HOLD 3 Menu Page button a The MENU PAGE button is used for setting up the ports as well as returning to the main screen from TRIPS or TOTAL displays 4 Select button 3 off a The Jackal has 3 soft buttons placed directly under the LCD These buttons will change function in different menus b The func...

Page 13: ...rmation at a time If more than three pieces of information are available the MENU PAGE or LEFT RIGHT can be used to cycle through the available information as described below Example 1 UP Example 2 UP Example 3 UP MORE INFORMATION ON SCREEN If more than 3 lines of information are displayed you can use the MENU PAGE or UP DOWN NAV button to scroll through the next available lines By using the LEFT ...

Page 14: ...e the input port select the number of decimal places displayed edit the alarms Other Allows the user to set in implement width m External run hold options alarm Settings notification settings as well as language control Output Allows the user to select output options from the Jackal Output as a frequency pulse radar external audible visual alarm batch trip function other external function if requi...

Page 15: ...hen this setting is turedn on for the input it extends the sample time and will steady the reading for slow rpm pulses If turned on for higher speed rpm pulses the display will take longer to respond changes in speed d FlowMeter Direct readout or batch flowmeter required e Slippage Meter GPS v Wheel Input sensor required f Generic Wizard You can choose the input screen position calibration factors...

Page 16: ... Magnet Used with 2 wire sensor Available Connections PAGE 4 This setup section assumes that physical wiring for the required sensors have been completed If not please refer to PAGE 7 on wiring requirements SETUP From the front screen press SETUP Highlight WIZARD press SELECT Highlight Area Speed Wheel press NEXT Highlight the INPUT number the speed is connected into the back of Jackal press NEXT ...

Page 17: ...STOP Press CALC This will divide the distance travelled by the number of pules registered MANUAL RATIO will now be updated to reflect the calibration factor Press NEXT For the Jackal to correctly read hectares acres an implement width needs to be entered Press EDIT You can RIGHT NAV button once press EDIT to change m to ft yd in Using the NAV buttons enter your implement width in m e g 18m Press E...

Page 18: ... you wish to also display Speed km hr on the front screen with the area covered Press YES The Wizard is now complete Press NEXT You will be returned to the Setup Screen Press EXIT On the front screen there will be area Ha and speed km h displayed THIS ENDS THE AUTO SET WIZARD SETUP FOR SPEED AREA METER ...

Page 19: ...acres an implement width needs to be entered Press EDIT You can RIGHT NAV button once select EDIT to change M to FT YD IN Using the NAV buttons enter your implement width in m e g 18m Press EXIT when done You can choose to enable the remote run hold input Further info PAGE 43 or edit the AlarmBeep in seconds Press NEXT Using the NAV buttons select how you would like the area to be displayed on the...

Page 20: ...Area in Hectare 2 decimal places Line 2 Speed km hr 1 decimal place Example 2 UP Line 1 Area in Acre 2 decimal places Line 2 Speed mi hr 1 decimal place Example 1 UP Setup to measure distance Units of measure UOM display for the front screen can be changed via SETUP FRONT SCREEN editing the appropriate input More details on PAGE 41 ...

Page 21: ...ighlight WIZARD press SELECT Highlight Area Speed GPS press NEXT Press the EDIT button to change the baud rate when the correct baud rate is selected the corresponding NMEA message will be acknowledged with a Y Press NEXT For the Jackal to correctly read hectares acres an implement width needs to be entered Press EDIT You can RIGHT NAV button once press EDIT to change M to FT YD IN Using the NAV b...

Page 22: ...ly acknowlege that you wish to also display Speed km hr on the front screen with the area covered Press YES The Wizard is now complete Press NEXT You will be returned to the Setup Screen Press EXIT THIS ENDS THE SETUP FOR SPEED AREA METER USING GPS INPUT Layout Example below Example 2 UP Line 1 Area in Hectare 2 decimal places Line 2 Speed km hr 1 decimal place ...

Page 23: ...f using a proximity sensor Any available Port B1 B6 SETUP From the main screen press SETUP This is example is using Input 1 B1 Fast Shaft over 1500RPM Coil or Prox Highlight WIZARD press SELECT Highlight TACHOMETER press NEXT Highlight the INPUT number X the sensor wire is connected into on the rear of the Jackal press NEXT Enable the input by pressing EDIT Leave the default value of pulse rev Usi...

Page 24: ... required Press NEXT Name the input if you desire Press EDIT e g SHAFT1 Press EXIT Press NEXT The Wizard is now complete Press NEXT You will be returned to the Setup Screen Press EXIT THIS ENDS THE SETUP FOR TACHO METER USING 1 MAGNET Example 1 UP Monitoring 1 shaft Example 2 UP Monitoring 2 shafts Re run the wizard again selecting the next port the sensor is connected to ...

Page 25: ...d x Flow Sensor 2 or 3 wire Available Connections PAGE 4 This setup section assumes that physical wiring for the required sensors have been completed If not please refer to PAGE 7 on wiring requirements NB 3 wire flow sensors need to be in B2 B6 If a 2 wire flow sensor is being used please use B1 SETUP This is example is using a 2 wire Sine Wave Coil flow sensor into B1 From the front screen press...

Page 26: ...e desired test volume has been reached press STOP Press CALC This will divide the measured amount by the number of pules registered MANUAL RATIO will now be updated to reflect the calibration factor Press NEXT Using the NAV buttons select how you would like the UOD to be displayed on the front screen Press NEXT You have the option to set Alarm Min Max points if required Using the NAV buttons selec...

Page 27: ...accept the new manual ratio PPL Using the NAV buttons select how you would like the UOD to be displayed on the front screen Press NEXT You have the option to set Alarm Min Max points if required Using the NAV buttons select EDIT as required Press NEXT Name the input if you desire Press EDIT or Press NEXT The Wizard is now complete Press NEXT You will be returned to the Setup Screen Press EXIT Exam...

Page 28: ...PAGE METER press NEXT Highlight the INPUT number X the WHEEL sensor wire is connected into on the rear of the Jackal press NEXT Press the EDIT button to change the baud rate when the correct baud rate is selected the corresponding NMEA message will be acknowledged with a Y Press NEXT As indicated drive above 3km hr Wheel input will then increment up displayed in Hz GPS speed will start to show As ...

Page 29: ...e Connections PAGE 4 This setup section assumes that physical wiring for the required sensors have been completed If not please refer to PAGE 7 on wiring requirements SETUP 1 Ensure there is product in bin tank 2 Have a bucket ready to catch the product 3 Have a set of scales e g Farmscan Ag Part 2199 ready to weigh the product From the front screen press SETUP Highlight WIZARD press SELECT Highli...

Page 30: ...tered MANUAL RATIO will now be updated to reflect the calibration factor Press NEXT It s recommended to do this test 3 times to get an average pulse count per kg Using the NAV buttons select how you would like the Unit Of Display to be displayed on the front screen I e kg Press NEXT You have the option to set Alarm Min Max points if required Using the NAV buttons select EDIT as required Press NEXT...

Page 31: ...E DOING THE FOLLOWING From the front screen press SETUP The Jackal should already be setup as a Flowmeter Refer to PAGE 24 Highlight OUTPUT press SELECT Press EDIT change the mode to BATCH TRIP Highlight the INPUT press EDIT to select the number X where the FLOW sensor wire is connected into on the rear of the Jackal Highlight UNIT press EDIT to change the Unit type to L Litres Highlight PULL LOW ...

Page 32: ...p guide on PAGES 24 26 for Flow Meter Setup o Suggested setup on Input B2 B6 o B1 can also be used depending on Flow meter signal 2 wire coil style From the front screen press SETUP Highlight FRONT SCREEN press SELECT Highlight the line in which the Flow Meter is connected to e g 3 Input 3 L min Press EDIT Highlight the UNIT press EDIT to change the unit to L Ha Press the UP NAV button Highlight I...

Page 33: ...line in which the Metering sensor is connected to e g 3 Input 3 kg Press EDIT Highlight the UNIT press EDIT to change the unit to kg Ha Press the UP NAV button Highlight IN1 press EDIT to change the Input X to where the METERING Sensor is connected i e 3 Input 3 Press the DOWN NAV button highlight IN2 press EDIT to change the Input X to where the WHEEL sensor is connected i e Input 2 Press EXIT tw...

Page 34: ... where the sensor wire is connected into on the rear of the Jackal press NEXT Enable the input by pressing EDIT Press EDIT to change the unit Full Empty H L high low On Off State will updated Live For example Low bin empty High bin full Test by placing hand around sensor Highlight Level select LEVEL This can be changed from Normal to Invert Can be used if Full empty is reversed Press NEXT Highligh...

Page 35: ...uirements CALIBRATION MANUAL The example below details setting up a LIQUID PRESSURE SENSOR From the front screen press SETUP Highlight WIZARD press SELECT Highlight GENERIC WIZARD press SELECT Highlight the INPUT number 7 8 to where the sensor wire is connected into on the rear of the Jackal press NEXT Enable the input by pressing EDIT Press EDIT to change the unit kPa psi bar Volt C i e kPa Highl...

Page 36: ...the UOD Unit of Display eg kPa Press NEXT when done You have the option to set Alarm Min Max points if required Using the NAV buttons select EDIT as required Press NEXT Name the input if you desire Press EDIT or Press NEXT The Wizard is now complete Press NEXT You will be returned to the Setup Screen Press EXIT Example 1UP Display of kPa THIS ENDS THE SETUP FOR A VARAIBLE VOLTAGE INPUT SENSOR ...

Page 37: ...eed to operate in The voltage will now be displayed e g 1 75v In the above example we can set the minimum of 1kPa by HIGHLIGHTING EDITTING the values as required Press SET This will copy the live voltage into the CAL LOW voltage point Repeat the previous 2 steps for the CAL HIGH values Highlight or confirm the UOD Unit of Display e g kPa Press NEXT when done You have the option to set Alarm Min Ma...

Page 38: ...N TRIP From the front page press TRIP The screen above allows you to SAVE RESET individual trips or view SAVED TRIPS By pressing the SAVE RESET you have the ability to Reset Trip Save Trip Reset All By pressing 2 Save Trip it will be stored in the SAVED TRIPS option You can now view the SAVED TRIPS You also have the ability to EDIT name the Trip or DEL ALL Delete All Trips When you return to the T...

Page 39: ...rpm Press EDIT to adjust these values Manual User setup Alarm points via the MENU FRONT SCREEN EDIT Input When the alarm point is reached e g over 3000rpm the line will FLASH notifying you of the alarm point Press ALARM to enter the page showing all Alarms active and inactive to reset the alarm In the example above Line 1 is over the alarm set point If it was below it would show 1v You have 3 opti...

Page 40: ...sh to be displayed on the front screen NB You can display multiple UOM on the front screen using only one input e g View Ha Ac at the same time 4 OTHER SETTINGS a Use this to define implement width for Ha Ac accumulation External Run Hold port if being used alarm options notifications Language English French German Bulgarian 5 OUTPUT a Use this only to setup the Jackal to output a pulse radar Alar...

Page 41: ...ge After selecting your input pressing the EDIT button allows you to enable disable the port CALIBRATION METHOD TARGET MANUAL RATIO When the input has been enabled using the NAV buttons navigates you through the calibration setup Here you can also select your calibration method N B Different inputs have different calibration methods Review the wizard setups for example calibration methods TARGET a...

Page 42: ...rent values You need to ensure the previous page Inputs are setup calibrated to continue with this method It is recommended that the wizard be used to assist setup FRONT SCREEN SETUP FRONT SCREEN Select the line you wish to display your information and press EDIT Enable the LINE by pressing EDIT Assign the input to be displayed Input 1 Name Wheel Refer example to the Right Unit km Decimals 1 decim...

Page 43: ...RONT SCREEN ORDER Example 3UP 3 Inputs Line 1 HA Line 2 Speed Line 3 Shaft 1 To re order Navigate to SETUP FRONT SCREEN Highlight the line you wish to move press ORDER It will now place a in front of the line like above Using the NAV buttons move the input to the desired line select PLACE When you now EXIT back to the front screen the order of lines have been changed Line 1 HA Line 2 Shaft 1 Line ...

Page 44: ...ble all accumulating values and alarms set in the Jackal without pressing the RUN HOLD on the Jackal itself NOTE When the EXTERNAL RUN HOLD is active on ANY input the function of the RUN HOLD button on the front screen is disabled The trigger wire can be applied to any of the 13 available inputs on the Jackal To enable maximum flexibility for this function NORMALLY ON or NORMALLY OFF mode can be s...

Page 45: ...e Beeps can be heard during the Alarm alert before acknowledgment is required The above option also allows the choice of having the audible alarm being used when the Jackal is on hold Press EDIT to change these options By default the Jackal is configured in ENGLISH Other languages can be selected by pressing EDIT English French German Bulgarian ...

Page 46: ...ed the Jackal will output a pulse frequency that can be adjusted in ratio to a selected input In the above example the pulse output will be 1 pulse meter Press EDIT to select Alarm In the above example the Jackal can be selected to leave the output disconnected or pull low when an alarm on a selected input is active This can be used to provide remote alarm functionality Example is High Low alarm s...

Page 47: ...g instructions The external GPS needs to be setup for GGA VTG RMC Either 1Hz or 5Hz and any baud rate is acceptable FRONT SCREEN SETUP GPS SERIAL When an external GPS is connected to Input A11 of the Jackal you can confirm view valid messages are being received In the SETUP screen you can change the Baud Rate confirm GGA VTG or RMC When a valid string is being received the N will change to a Y ...

Page 48: ...mscan Ag Pty Ltd ABN 92 143 803 070 11 493 South Street Toowoomba QLD 4350 AUSTRALIA Ph 61 7 4602 4150 Fax 61 7 4602 4151 sales farmscanag com 2010 2015 Farmscan AG Pty Ltd AM JACKAL 3 September 2015 V2409 ...

Reviews: