Oil thermometer defected, picture 1
•
If the oil thermometer is defected, it is a symp-
tom that the oil has overheated and the gauge
has expanded and broken the thermo-meter.
•
NOTE! Max. oil operation temperature is
about 80
o
C. See section ”Overheating hyd-
raulic oil”.
•
Normally the colour of the oil is almost clear. If
the hydraulic oil is black, it is an indication of
overheated oil. If the oil colour is gray, there is
water mixed to it.
•
In either case it must be changed immediately.
Saw does not cut the wood, picture 2
•
If the saw does not slide over the wood by its
own force, the chainsaw is blunt or the chain has
been mounted the wrong way round.
•
If the saw cuts the wood fractionally and then
stops, it is an indication of that one side is blunt
or one side only has been sharpened.
•
See operating- and maintenance instructions
section: “Chainsaw maintenance”.