MASTERSPLIT WP30
36
1
ELECTRIC ENGINE PROBLEMS
Emergency stop-switch is engaged
•
Ensure that the emergency stop-switch (red) is
not engaged.
Electric switch in wrong position
•
Start the electric engine by turning the switch
into a “ Y “ position. When the engine starts turn
the switch immediately back to the “Δ” position.
(figure 1)
Warning!
•
Long operating times in the “Y” position causes
damage to the electric engine!
Wrong coupling
•
Check the power transmission and cables.
•
Check with the general indicator that all gears
are connected to the power transmission.
NOTE!
Recommended max. length of the power cord is
50 m
•
Ensure that the power cord is not coiled (the po-
wer transmission is hindered).