54
│
58
Manual
MONSUN MC | ME
TROUBLESHOOTING
Defects can be often removed in simple and quick way. Before you ask for a service, try to remove
the defect by yourselves using following tables.
Electronics
Defect
Cause
Remedy
The electronics
do not operate.
Burn fuse.
Disconnected supply.
Insufficient supply voltage.
Replace the fuse.
Check the supply cable connection.
Check the voltage.
The voltage needs to be 12 V.
Fan revolutions
falls to half
value.
Impulses are invoked only
with one groove on the
drive shaft.
Adapt setting of the fan revolutions
sensor.
Fan revolutions
are zero.
Sensor without voltage.
No impulses.
The sensor is defective.
Check the electric supply.
Adapt setting of the fan revolutions
sensor.
Check the fan revolutions sensor,
replace it when needed.