44
│
58
Manual
MONSUN MC | ME
Never start the fan if you are not sure with correct sensor setting. This can permanently
damage the sensor.
Check a smooth rotation of the shaft without touching the sensor. Carefully manually turn the fan.
The shaft shall not touch the sensor but should invoke to impulses per one revolution. The groove
provides a switching impulse when passing the sensor, the diode on the sensor blinks.
Tighten the nut on the sensor.
Setting of the fan sensor.
Hydraulic hoses
Hydraulic hoses get worn and age without visible external signs. Based on valid international
regulations the hydraulic hoses need to replaced every 6 years.
Ensure the hoses are without pressure when changing them.
Replacement of harrow fingers
Release screws and nuts.
Replacement of the harrow.
Fix the harrow handle and firmly tighten.
Replacement of harrow fingers
Sensor with light diode
Cam
Sensor with
light diode
Belt
Nuts
Harrow