46
(MT11 - Gb2006)
Si 26MO/1
I
NTERCOMS
*
V
IDEOINTERCOMS
*
T
ELECOMMUNICA
TION
INTERCOM SYSTEM WITH SECONDARY DOOR STATIONS AND 1 MAIN COMMON STATION (multiple entrance)
Q.ty
Article
Description
...
KM 810W
Compact series intercom with 1 call button
...
ST 720W
Studio series modular intercom
...
PT 510EW
Project series intercom with 1 call button
...
PT 526EW
Project series modular intercom
X
PRS240
Power supply with electronic ringing generator
1
PRS220
Power supply
X
1473
Exchanger
1+X
PA **
Door release push-button (optional)
1+X
SE **
Electric door lock (12VAC-1A)
Door station series Mody (for right item set see on pages 16÷19)
1 row
2 row
...
MD71÷74
MD71÷74
Module frames with back box
1+X
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
1+X
MD82 ÷ 812
MD82 ÷ 812
Hood covers
1+X
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters with module frames
1+X
MD30
MD30
Electric door speaker (amplifier)
Door station series Matrix (for right item set see on pages 24 and 25)
...
MA71÷73
Module frames with back box
1+X
MA10P-11P-12P
Modules with integrated audio amplifier
...
MA20-22-24
Blank and button modules
...
MA61÷63
Front frames
...
MA91 ÷ 93 *
Rain shelters with module frames
Door station series Profilo (for right item set see on pages 28 and 29)
...
PL71÷73
Module frames with back box
1+X
PL10P-11P-12P
Modules with integrated audio amplifier
...
PL20 ÷ 24
Blank and button modules
S
T
-
P
T
-
K
M
Floor call
This work diagram allows for differ-
entiating the floor-call from the call
from the push-button panel.
... Refers to number of users.
X Refers to the number of stairways.
* Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Working instructions.
As the basic system described on page 36, with the following variations:
- The audio functions and door lock opening are automatically switched to the door
station which has made the call and remain in this state until a call from another
entrance is received.
- Services to secondary door stations are independent and can be operated at the
same time.
Notes
- You can also use Prestige and TM push-button panels. For the latter series you must
request the version with separate common terminals.
- For the connection of name-plate lamps, read notes 6, 7 and 8 of the installation
instructions on page 35.
- For wires dimensioning refer to the installation recommendations and table on page
35.
- Telephones can be used instead of intercoms (see “telecommunication” section).
- For other types of push-button panels see pages 30 and 31 or the general catalogue.
common of buttons 1
and 2
to separate common of
buttons cut here
common of buttons 3
and 4
The main entrance push-button panel must
have separate common terminals. One common
terminal for each secondary door station. Buttons of
the Mody series can be divided into 2-button groups.
Common terminals of Matrix and Profilo push but-
tons cannot be separated.
Call button modules series Mody
PRS240
9
9
FP
FP
7
PT526E
PT510E
C+
ST720
KM810
Floor-button
Floor-button