134
(MT11 - Gb2006)
Si 42MO/3
I
NTERCOMS *
V
IDEOINTERCOMS
*
T
ELECOMMUNICA
TION
VIDEO INTERCOM SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS, ONE OF WHICH ONLY AUDIO
Q.ty
Article
Description
...
WB8600
Compact videointercom Flat + bracket
...
8083
Compact videoin b back box
...
WB8600
Compact videointercom bracket
...
WB7100
Studio series m bracket
...
WB700
Studio series in bracket
...
DV2-4
Video distributor
1
1281
Power supply
1
1282E
Timer
1
1473
Exchanger
2
PA **
Door release button (optional)
2
SE **
Electric door lock (12Vac-1A)
Mody series external door station (for the composition see pages 96÷99)
1 row
2 row
...
MD71÷74
MD71÷74
Back boxes and module frames
2
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
2
MD82 ÷ 812
MD82 ÷ 812
Hood covers
2
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters and module frames
2
MD30
MD30
Electric door speaker (amplifier)
1
MD41
MD41
Camera
Matrix series external door station (for the composition see pages 102÷103)
...
MA71-72-73
Back boxes and module frames
...
MA61-62-63
Front frames
...
MA20-22-24
Blank and button modules
1
MA10P-11P-12P
Modules with audio amplifier
1
MA42-43
Cameras with integrated audio amplifier
...
MA91-92-93*
Rain shelters and module frames
Profilo series external door station (for the composition see pages 106÷107)
...
PL71-72-73
Back boxes and module frames
...
PL20÷24
Blank and button modules
1
PL10P-11P-12P
Modules with audio amplifier
1
PL40P-41P-42P
Cameras with integrated audio amplifier
Connection of 1281E power supply-timer
instead of 1281 plus 1282E.
By adding 1281E to the schematics on page
135 instead of 1281 plus 1282E, the system
working will modify as follows:
- switching-OFF at the end of the timing only
PA
PA
SE
SE
PRS210
1282E
1281E
2
2
1
5
1471
S
2
6
A
5
2
3
F
Connection of 2 door locks with simultaneous opening
If it is necessary to operate the 2 door locks of the system at the
same time, you must:
- add a 12Vac transformer with suitable power (type PRS210)
- add a 12Vac relay (type 1471)
- make the connections as shown in the diagram below.
Control switching ON deactivation
To activate the control switching ON from the
intercoms only when the system is in standby,
it is necessary to install a relay (type 1471 or
1472) and connect it as shown on the dia-
gram.
to 5 of the videointercoms
1281E
1282E
1473
2
2
2
5
1472
2 3
2 7
4
F
H
6
to the video inter-
coms
... Refers to number of users.
* The rain shelter is used in the place of the back box and hood cover.
** Articles not supplied by ACI Farfisa.
Working instructions. See page 115.
Notes
- For the connection of name plate lamps read notes 6, 7 and 8 of the
installation instructions on page 111.
- If the control switching ON is necessary, connect terminal 4 of the timer
(dashed wire).
- To install a colour system, the ST7100CW video intercoms and the
MD41C, MA42C, MA43C, PL40PC, PL41PC or PL42PC camera must
be used.
- For wires dimensioning and video connection refer to the installation
instructions and table on pages 111÷113.
- For one-way systems connect the coaxial cable to the monitor bracket
directly, without using the video distributor.
- Telephones can be used instead of intercoms (see “telecommunication”
section).
- For other types of push-button panels see the general catalogue.
230V
127V
0
1281E
X
S
5
A
H
4
3+
F
C+