206
(MT11 - Gb2006)
In addition to the traditional functions, the PABX allows for intercom
connection to your own entrance or to the building system intercom and
intercommunicating service between Farfisa dedicated telephones
(art. ST740) or pulse/DTMF standard telephones.
The PABX are sold with basic programming by default. For the intercom
connection or for changing the default programming, carefully read the
instructions manual supplied with the product.
Technical data
FT105P
FT208P
Supply voltage (+6÷-10%):
230Vac
230Vac
Maximum power consumption:
16W
18W
Power consumption in stand-by:
10W
10W
Input protection fuse:
0.315A
0.315A
Maximum distance of an extension line with 0.6 mm2
telephone pair:
350m
350m
Dimensions:
226x254x66
226x254x66
Weight:
1.3 Kg
1.4 Kg
Operating temperature:
0°÷40°C
0°÷40°C
Maximum humidity permitted:
85%RH
85%RH
Number of external lines:
1
2
Number of extension lines:
5
8
Number of DTMF receivers:
1
2
Simultaneous internal conversations:
2
2
Simultaneous external conversations:
1
2
Paging communication:
1
1
Intercom calls (additional board):
1 or 2
1 or 2
Storing of data in case of power failure:
EEprom
EEprom
Extension lines in emergency mode:
41
41 and 42
Extension line for facsimiles, modems, answering machines:
45 *
48 *
Microprocessor control with recorded program
Solid-state switching matrix
2-wire internal telephone network
* The other extension lines can also be used but in this case the use of the general call function is not recommended.
SAFETY RULES
Only use the devices for the purpose it was designed for. The manu-
facturer is not responsible for possible damages arising from im-
proper, incorrect or unreasonable use.
The devices complies with the EEC directives (CE European Mark).
The installation must comply with the CE regulations in force.
A disconnecting and protection switch must be placed before the
PABX in the installation.
Before powering up the PABX, make sure that the rating complies with
the power mains.
Never open the devices when turned ON.
In case of failure, malfunctioning or modification of the installation,
disconnect the power mains by means of the general switch and
contact specialized personnel.
EMERGENCY
In case of power failure, the following lines can be used to make/receive
calls:
for FT105P extension 41
for FT208P extension 41 for external line 1
extension 42 for external line 2
An EEPROM memory guarantees the storing of the general program-
ming data (or system data) and restore them when the power is restored.
FT105P. PABX with 1 external and 5 extension lines
FT208P. PABX with 2 external and 8 extension lines
PABX
I
NTERCOMS *
V
IDEOINTERCOMS *
T
ELECOMMUNICA
TION
F
A
R
T
E
L
10
"
66
254
225
8
"
8
/
7
2
"
8
/
5