56
(MT11 - Gb2006)
Table for choosing intercoms and accessories for the required type of installation
Number of inter-
Studio
Project
Compact
Application dia-
communicating ST 720W ST 701
SR41
PT526EW
PT501
SR41
KM810W
ST 701
SR41
gram on page:
2
2
2
2
2
0
2
2
2
2
76
3
3
6
3
3
3
3
76
4
4
12
4
4
8
4
76
5
5
20
5
5
15
5
57
6
6
30
6
6
24
6
77
7
7
42
7
7
35
7
77
8
8
48
8
*
9
9
63
9
*
10
10
80
10
*
PA
SE
MD71
MD100
1
2
230V
127V
0
G
2
7
X
D
A
PRS226E
C+
RP100
C
1
2
UP11
UP100
P2
P1
Si 211L/5
I
NTERCOMS
*
V
IDEOINTERCOMS
*
T
ELECOMMUNICA
TION
5 INTERCOMMUNICATING INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION WITH COMMON CALL. Call from external
door station with alternate current.
Q.ty
Article
Description
...
ST 720W
Studio series modular intercom
...
ST 701
Single button unit
...
PT526EW
Project series modular intercom
...
PT501
Single button unit
...
SR41
Electronic buzzer
1
PRS226E
Power supply-switcher
1
PA **
Door release push-button (optional)
1
SE **
Electric door lock (12VAC-1A)
Door station series Mody
1
MD71
Module frames with back box
1
MD11
Module for electric door speaker
1
MD81
Hood cover
1
MD91*
Rain shelter with module frames
1
MD30
Electric door speaker (amplifier)
Door station series Matrix
1
MA71
Module frames with back box
1
MA11P
Module with integrated audio amplifier
1
MA61
Front frame
1
MA91*
Rain shelter with module frames
Door station series Profilo
1
PL71
Module frames with back box
1
PL11P
Module with integrated audio amplifier
... Refers to number of users (see table).
* Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Working instructions. See page 36.
Notes
- Do not forget to connect terminals C of the additional buttons and install the
SR41 electronic buzzer in each intercom.
- If only 2 intercommunicating intercoms are requested, even Compact
series can be used (see page 76).
- When using intercom PT526E you must connect the common terminal of
the additional buttons to terminal 7.
- For the connection of name-plate lamps, read notes 6 and 7 of the
installation instructions on page 35.
- For wires dimensioning refer to installation instructions and table on page
35.
- For other types of push-button panels see pages 30 and 31 or the general
catalogue.
S
T
U
D
I
O
P
R
O
J
E
C
T
Application diagram
When using MD100, RP100, UP11 and UP100 amplified external
door stations place this diagram on the diagram on page 57 and
line it up with the riser.
Warning.
- In the external door stations RP100
cut the jumper W1.
- In the external door stations UP do
not connect the yellow wire and
insulate it.
- For alternate current wires refer to
note 6 of the installation instruc-
tions on page 35.
* upon request
7
1
3
5
2
0
9
P1
P2
P3
P1
4 3
SR41
5
1
9
2
3
0
P1
P2
C
P
C
P
JP2
4 3
SR41
ST 720
PT526E