130
(MT11 - Gb2006)
Si 42MO/1
I
NTERCOMS *
V
IDEOINTERCOMS
*
T
ELECOMMUNICA
TION
VIDEO INTERCOM SYSTEM CONNECTED TO TWO EXTERNAL DOOR STATIONS
Q.ty
Article
Description
...
WB8600
Compact videointercom Flat + bracket
...
8083
Compact videoin b back box
...
WB8600
Compact videointercom bracket
...
WB7100
Studio series m bracket
...
WB700
Studio series in bracket
...
DV2-4
Video distributor
1
1281
Power supply
1
1282E
Timer
1
1273TV
Exchanger
2
PA **
Door release button (optional)
2
SE **
Electric door lock (12Vac-1A)
Mody series external door station (for the composition see pages 96÷99)
1 row
2 row
...
MD71÷74
MD71÷74
Back boxes and module frames
2
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
2
MD82 ÷ 812
MD82 ÷ 812
Hood covers
2
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters and module frames
2
MD30
MD30
Electric door speaker (amplifier)
2
MD41
MD41
Camera
Matrix series external door station (for the composition see pages 102÷103)
...
MA71-72-73
Back boxes and module frames
...
MA61-62-63
Front frames
...
MA20-22-24
Blank and button modules
2
MA42-43
Cameras with integrated audio amplifier
...
MA91-92-93*
Rain shelters and module frames
Profilo series external door station (for the composition see pages 106÷107)
...
PL71-72-73
Back boxes and module frames
...
PL20÷24
Blank and button modules
2
PL40P-41P-42P
Cameras with integrated audio amplifier
... Refers to number of users.
* The rain shelter is used in the place of the back box and hood cover.
** Articles not supplied by ACI Farfisa.
Working instructions. See page 115.
Notes
- For the connection of name plate lamps read notes 6, 7 and 8 of the installation instructions on page 111.
- If the control switching ON is necessary, you must connect the dashed wires and the two terminals 1C and PC in each video intercom.
- To install a colour system, the ST7100CW video intercoms and the MD41C, MA42C, MA43C, PL40PC, PL41PC or PL42PC camera must be
used.
- For wires dimensioning and video connection refer to the installation instructions and table on pages 111÷113.
- For one-way systems connect the coaxial cable to the monitor bracket directly, without using the video distributor.
- Telephones can be used instead of intercoms (see “telecommunication” section).
- For other types of push-button panels see the general catalogue.
PA
PA
SE
SE
PRS210
1282E
1281E
2
2
1
5
1471
S
2
6
A
5
2
3
F
Connection of 2 door locks with simultaneous opening
If it is necessary to operate the 2 door locks of the system at the same time, you must:
- add a 12Vac transformer with suitable power (type PRS210)
- add a 12Vac relay (type 1471)
- make the connections as shown in the diagram below.
1282E
1281E
1273TV
2
2
2
2
5
11
1472
2 3
2 7
213
4
P
F
H
3
6
Control switching ON deactivation
To activate the control switching ON from the intercoms only
when the system is in standby, it is necessary to install a 2-
exchange relay (type 1472) and connect it as shown on the
diagram.
to 5 of the videointercoms
to the videointercoms
Connection of 1281E power supply-timer
instead of 1281 plus 1282E.
By adding 1281E to the schematics on page
131 instead of 1281 plus 1282E, the system
working will modify as follows:
- switching-OFF at the end of the timing only
230V
127V
0
1281E
X
S
5
A
H
4
3+
F
C+