DS1 is a diagram reference
VIDEO INTERCOM SYSTEM WITH SECONDARY VIDEO STATIONS AND 2 MAIN COMMON VIDEO STATIONS (multiple entrance)
Q.ty
Article
Description
...
WB7100
Studio series m bracket
...
WB700
Studio series in bracket
...
DV2D-4D
Video distributor
2+X
1281
Power supply
1+X
1282E
Timer
2xX
1273TV
Exchanger
1
1471
Relay unit
2+X
PA **
Door release button (optional)
2+X
SE **
Electric door lock (12Vac-1A)
2
D **
Min. 100V-1A diodes (1N4007 type)
Mody series external door station (for the composition see pages 96÷99)
1 row
2 row
...
MD71÷74
MD71÷74
Back boxes and module frames
2+X
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
2+X
MD82 ÷ 812
MD82 ÷ 812
Hood covers
2+X
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters and module frames
2+X
MD30
MD30
Electric door speaker (amplifier)
2+X
MD41D (
1
)
MD41D (
1
)
Camera
Matrix series external door station (for the composition see pages 102÷103)
...
MA71-72-73
Back boxes and module frames
...
MA61-62-63
Front frames
...
MA20-22-24
Blank and button modules
2+X
MA42-43
Cameras with integrated audio amplifier
2+X
CV01
Video signal converter
....
MA91-92-93*
Rain shelters and module frames
Profilo series external door station (for the composition see pages 106÷107)
...
PL71-72-73
Back boxes and module frames
...
PL20÷24
Blank and button modules
2+X
PL40P÷42P
Cameras with integrated audio amplifier
2+X
CV01
Video signal converter
7a
7
1273TV
(DS1)
.
... Refers to number of users.
X Refers to number of secondary door stations.
* The rain shelter is used in the place of the back box and hood cover.
** Articles not supplied by ACI Farfisa.
(
1
) For other types of cameras see page 108.
Working instructions. See page 115.
Notes
- For the connection of name plate lamps read notes 6, 7 and 8 of the installation
instructions on page 111.
- Connect the video intercom terminal 4 (wire shown with dotted line) if the control switch
on from the secondary door station is required.
- To install a colour system, the ST7100CW video intercoms and the MD41C, MA42C,
MA43C, PL40PC, PL41PC or PL42PC camera must be used.
- For wires dimensioning and video connection refer to the installation instructions and
table on pages 111 and 114.
- Telephones can be used instead of intercoms (see “telecommunication” section).
- For other types of push-button panels see the general catalogue.
Connection of two door locks, of which the secondary is
always activable, in a system with multiple entrance
For this option it is necessary to install a diode (100V-1A; type
1N4007) between terminals 7 (cathode) and 7a (anode) of every
secondary exchanger.
Control switching ON deactivation
To activate the control switching ON from the inter-
coms only when the system is in standby, it is neces-
sary to install a relay (type 1471 or 1472) and connect
it as shown on the diagram.
to the video in-
tercoms
common of buttons 1 and
2
to separate the common of
buttons cut here
common of buttons 3 and
4
The main entrance push-button panel must
have separate common terminals. One common
terminal for each secondary door station. Buttons of
the Mody series can be divided into 2-button groups.
Common terminals of Matrix and Profilo push but-
tons cannot be separated.
Mody series button module
Connection of 1281E power supply-timer in-
stead of 1281 plus 1282E
By adding 1281E to the schematic on page 169
instead of 1281 plus 1282E, the system working will
modify as follows:
- switching-OFF at the end of the timing only
230V
127V
0
1281E
S
F 3+
C+
X
H
5
Power supply-timer of the secondary entrance
Power supply-timer of the main entrance
230V
127V
0
1281E
5
C+
X
H
F
S
3+
A
4