76
15 Security Settings
15.1 Alarm Input
Alarm input detection interface: Used to connect devices such as infrared sensors,
smoke detectors, and gas alarms.
When the alarm input is triggered, it can send a short message to a designated server
address or make a call to a specified number, and play an alarm ringtone locally. This
facilitates quick response by management personnel.
Users can modify related configuration parameters through the webpage at
[Security
Settings] >> [Alert] >> [Input Alarm Settings],
or via the device
[Menu] >> [Security
Setup] (enter security password).
Parameters
Description
Basic Settings
Ringtone
Duration
When the input interface triggers an alarm, if the alarm sound is
enabled, specify the duration of the alarm sound.
Input &
Tamper
Server
Address
Configure the remote response server address, including the remote
response server address and the triggered alarm server address.
When the input interface or tamper is triggered, it will send a short
message to the server. The server address supports IP:PORT or SIP
number.
Information
The alarm information to be sent:
Parameters can be replaced with actual values. The supported
parameters include:
Model, replace with the actual model name
Active_user, replace with the actual SIP username
Mac, replace with the MAC address of the device
IP, replace with the IP address of the device
Trigger, replace with the triggered interface, such as input1,
input2, etc.