Manual FältCom ECII SE Eng
Page 21 of 36
Note that the alarm is transmitted 1 minute after completion of programming mode.
7.2 More available functions
7.2.1 Change of time delay for alarm button
You can change the time that the alarm button must be pressed down before an alarm is
activated. The default time is 4 seconds, but this time may be changed to between 2 and 30
seconds. Note that the selected time must always be shorter than the time posted next to the
alarm button in the lift.
<Time in seconds (02–30)>
Note that the time always must be entered with two digits. Also note that it is the delay before
activating that is programmed which means it will take additionally about two seconds before
the actual call is made.
7.2.2 Connection
via
telephone exchange
If the lift phone is connected to an extension in a telephone exchange, the exchange must
issue a dialing tone before it will be possible to dial the alarm number. This is usually
achieved by dialing a zero from the telephone and then waiting for the dialing tone. FältCom
ECII SE handles this by having the alarm number start with a zero and an asterisk. The
asterisk after the zero makes the lift phone wait two seconds for a dialing tone. The waiting
time is increased if you press
two or more times. Every pressing increases the waiting
time by 2 seconds.
The primary alarm number, for example, is programmed as follows:
<Area code + subscriber number>
7.2.3 Connections to telephone line with Hot-Line functions.
If the lift phone is connected to a telephone line with Hot-line function an adequate pause time
must be added so that the pre-programmed telephone number is called up. The length of the
pause might be different in different telephone exchange solutions. The time which is needed
to make the Hot-Line call has to be known. Afterwards must a sufficient number of
-
symbols be programmed to achieve correct time of pause.
Observe that each one of the
- symbols represents a pause time of two seconds. There is
no need to program any telephone number since the Hot-Line function takes care of that.
<
+ the number of
-symbols to reach adequate waiting time >
Example: Connect a standard telephone and lift up the receiver. Measure the waiting time for
Hot-Line function before the call is made. Divide the number of seconds with two. The answer
will be the number of
-symbols which must be programmed. To be sure choose one extra
-symbol.
7.2.4 Activation of automatic test alarm
This function calls a test alarm receiver to check the connection. Note that test alarm shall
only be programmed if the function has been ordered at the alarm receiver. When the test