Note: this re-programming must be done while the DC/DC converter is connected.
See more under section
Busy line function.
6.7 Connection to loop amplifier
To enable passengers with impaired hearing to communicate with alarm centre there is a
possibility to connect a loop amplifier. Contact your local distributor for information about
approved loop amplifier to be used with FältCom ECII SE.
Connect the output marked “LOOP AMP” to the loop amplifier. The loop amplifier must work
during power failure. Connect it to a power supply that is working during power failures.
6.8 Connection of external pictogram
It is possible to connect external lamps to indicate alarm status on the lift phone according to
EN81:70 with the system component Pictogram Driver. It contains a DC/DC-converter and
drive circuits for external lamps. It is connected to the output marked DC/DC, to 12V
emergency power and to the external lamps. There is also a system component called
Pictogram Board with same functionality as Pictogram Driver but is delivered without the
DC/DC-converter. Contact your distributor for more information.